    Wifi extender running on electrical cables

    https://www.argos.co.uk/product/2009542?istCompanyId=a74d8886-5df9-4baa-b776-166b3bf9111c&istFeedId=c290d9a9-b5d6-423c-841d-2a559621874c&istItemId=rrlqatwlt&istBid=t Will the above be something similar to what you have?
  2. N

    Wifi extender running on electrical cables

    I'm trying to get a decent WiFi extender and come across this one from argos. It seems to suggest the connection is boosted or is stronger by having them plugged in to the same electrical circuit? How does 2.5mm cable, supposedly fitted decades ago, make the wifi connection stronger...
  3. N

    Cable getting discoloured / lifespan of cables

    The connector is new installed Dec 23. It can't be both connectors were bad despite the terminal block box was 24 years old. It will still be 240v to the boiler end. The cable that connects from boiler to the red wire at boiler end is fine and doesn't change colour. The cable that connects to...
  4. N

    Cable getting discoloured / lifespan of cables

    It is solid core. That's the issue no other cables are affected. The boiler end wasn't affected. However back in December one of the other cables in the programmer was silver? What bigger size would you recommend?
  5. N

    Vaillant ecotec 438 clunking noise

    Random the boiler makes clunking noise as if water is being forced through it?? Here's a clip
  6. N

    Cable getting discoloured / lifespan of cables

    This is a new wago junction box. Previously it did the same thing in an ancient wiring centre which had terminal blocks. That was in place for 24 ye Boiler is in garage, pump in loft. 15-20 meters of wiring I'd say
  7. N

    Cable getting discoloured / lifespan of cables

    This is a new wago junction box. Previously it did the same thing in an ancient wiring centre which had terminal blocks. That was in place for 24 years
  8. N

    Cable getting discoloured / lifespan of cables

    It's in the loft, other conductors perfectly fine. The conductor is in one of the terminals of the wago junction box. I haven't tried cleaning it as you mentioned but instead strip the cable.
  9. N

    Cable getting discoloured / lifespan of cables

    What causes a cable to get discoloured? I have a heating/hot water issue however the cable that comes from the boiler to the pump gets discolored on one side (on the side that connects to the pump). The discoloration can take a few weeks. This then causes a delay for the heating/water to come...
  10. N

    Heat lamp / infra red

    Lol its not a catering heat lamp but one a physician would use!
  11. N

    Heat lamp / infra red

    Used for pain relief https://www.amazon.co.uk/dp/B0BS9D3MTP/ref=sspa_mw_detail_1?ie=UTF8&psc=1&spc=MTo1NTMwMDMzMTQxNzQwMjA6MTcwNTg2NjA1MTpzcF9waG9uZV9kZXRhaWw6MzAwMTE0NDU5NzcxNDMyOjo6Og&sp_csd=d2lkZ2V0TmFtZT1zcF9waG9uZV9kZXRhaWwp13NParams
  12. N

    Heat lamp / infra red

    I'm trying to buy a decent heat lamp, the one with the red bulb, but they're quite poor and not many about. I've seen some with a holder only without a stand. Ideally I need one with a stand. Can I make my own? What sort of cable size would I need for a bulb that dishes out 100-275w? And...
  13. N

    Rads only heating at the top.

    Perhaps a YouTube video will help him, written text is easily misinterpreted.
  14. N

    Central heating pipes HW cylinder against joists

    Very small amounts couple of mm
  15. N

    Central heating pipes HW cylinder against joists

    No space and very risky. Could strike pipe and have further problems...see pink circle in pic
  16. N

    Central heating pipes HW cylinder against joists

    One of the issues I've encountered is that central heating pipes against joist that cause buzzing or vibration noise when CH is on. It's worse with HW as the HW cylinder is made on a timber frame and again that's sat on joists. I've tried using bits of pipe insulation against one of the CH...
  17. N

    Grundfos ups3 making noise

    Hard bits. Poweflush was done in Oct with old ups3. I was present water was crystal clear. Even bleeding rads water is clear. Water from ups3 today was light yellow. The magna clean was full. This is first time i opened it since fitted in Oct. I will check it daily from now on. Is there...
  18. N

    Grundfos ups3 making noise

    I've put it on c3 for nearly an hour now and it's 40w and 0.8 Look what i found inside the ups3
  19. N

    Grundfos ups3 making noise

    24w anf 0.6m3 With it on 5 on blue side the rads are bit warmer at the bottom, before on the ups3 they were cold. Bathroom towel rad still cold. If i put it on 6m it will definitely heat up. Other issue is with HW on same time it would cause rads to go colder with a lower setting On 5 red side...