Search results

  1. B

    Lights in Cupboard containing Lift control cabinet.

    Many thanks for that info, much appreciated.
  2. B

    Lights in Cupboard containing Lift control cabinet.

    Does the Lighting in a small cleaners cupboard that also contains an enclosure for the Lift control equipment, need to be of a specific type ? ie fire retardant, the one in there at the moment is a standard IP65 bulkhead.
  3. B

    PAXTON DOOR ENTRY- POWER SUPPLY.

    I did find some cheap alternative's, some as cheap as a £20. I am determined to have a go at doing one, I will report back if any success .
  4. B

    PAXTON DOOR ENTRY- POWER SUPPLY.

    Has any one tried repairing a Paxton Net 2 Door entry system 12V power supply, model number 411-501. They all seem to suffer with the same dead fault, no 12V out put. When defective they still have HT on the smoothing cap and the collector of the chopper transistor. I notice two small 4 pin...
  5. B

    Russ Andrews super Fuse !!

    The debate is their claim that a different fuse in the 13 Amp attached to the Audio equipment can improve the sound quality , a claim which I think most Electrical Engineers would dismiss as complete nonsense.
  6. B

    Russ Andrews super Fuse !!

    Flameport, with ref to the correct coloring, a very good point and you are correct.
  7. B

    Is my oven element on its way out?

    Sometime prior to going O/C Elements go out of shape and the Fan (assuming its a fan oven) strats fouling on the element, causing all sorts of noises. Try taking the cover off for a better look.
  8. B

    Russ Andrews super Fuse !!

    So if one was to brake an example it open and examine, the conductor, what would be so different about that strand of wire, that it improves the sound quality of the piece of equipment that previously had it fitted in IT`S 13A PLUG. Incidentally they also do a gold plated version at £75 each ...
  9. B

    Russ Andrews super Fuse !!

    I know different products from the Russ Andrews web site have been discussed on this Forum with some healthy scepticism. But I now see they are retailing the, "Russ Andrews super Fuse ", a replacement for your standard BS1362 at £25 a pop ! A pretend sales enquiry, assured me they comply with...
  10. B

    Maintained Emergency light in Bathroom.

    Yes I tried to get the type with the test button, could not see them stocked any were. So were ok with a Key switch then ?
  11. B

    Maintained Emergency light in Bathroom.

    Picked up on a fire safety audit is a missing maintained fire exit light in a large bathroom located in a hostel, the bathroom has two doors one leading to the outside of the building designated as a fire escape . Question is can a engineers emergency light test switch be located in a bathroom...
  12. B

    Table Lamp PAT Test advice.

    I think this thread has gone off course, a bit. On my first visual inspection of this lamp in question, my suspicions were aroused by what I perceived as the attached poor quality quality mains flex. I initially thought it had been rewired with that clear two core speaker cable, but further...
  13. B

    Table Lamp PAT Test advice.

    That's right, two label's on the mains flex, but neither have any indication of it being double insulated. But is the unmarked flex also a reason to fail it ?
  14. B

    Table Lamp PAT Test advice.

    I have been given some 240volt table lamps to PAT Test, that were recently purchased, from a well known large retailer. The lamp shade and the supporting stand and body are all made of metal. There are no markings to indicate if it is double insulated appliance. It is fitted with clear twin...
  15. B

    Leaking Beko Dishwasher.

    I had a close look at the bottom wash arm, and you were correct, it had a split each side along the join, I have glued it together with epoxy resin, and it now working fine, no more leaks. I have ordered a replacement pair, as I don't expect the adhesive to last for long. Your advice was much...
  16. B

    Leaking Beko Dishwasher.

    Thanks for your reply, you are correct DW663, I will take a close look at the lower arm. I did notice the door seal is a popular listing on ebay, so I assume a common failure, mine looks ok but ?? Is it worth getting one to try?
  17. B

    Sebo X4 vacuum cleaner

    I have had 2 or 3 Sebo X4`s Vacs, were the moulded plug has gone open circuit( O/C) inside, chop it off with about 6 inches of the flex then bell it out again. I have also changed a few Sebo on off switches as well, but the cable should read no more than a couple of ohms from one end to the...
  18. B

    Leaking Beko Dishwasher.

    We have a Beko Dishwasher Model BW663, that leaks from the bottom right hand corner of the door, nearly every time we us it. I have had a good look at the door seal, and cannot see anything obvious, the right hand side looks no different than the left. All channels are free from grease, cant...
  19. B

    Logik cooker LDOC60W and its clones.

    That thought crossed my mind at the time as well, but I could see no scorch marks, but then again their all thick with grease and carbon. Only once did one trip the incomer, and that was after MCB feeding it had been reset about 4 times in succession. As to there age, they average 4 years at...
  20. B

    Logik cooker LDOC60W and its clones.

    Thanks for the reply, yes I am familiar about the ingress of moisture into Elements, but the resultant earth leakage, usually just trips the RCD or RCBO. When I have encountered this particular problem, it really goes " bang", on one occasion it even took out one of the 3 phase incommers ! I...
Back