  1. secureiam

    Fitting a second Premier keypad with a standard keypad to a Texcom Excal box

    It isn’t compatible. excel is a Veritas system, so Veritas led and lcd keypads only
  2. secureiam

    Texecom Recipes and Timers

    Not seen you you’re recipe so can’t confirm it’s correct. There is a guide available I believe on how to do this, if you followed that guide it’s should be fine, if it’s not working need to see what you have to pass comment
  3. secureiam

    Texecom Premier Elite 24 Unable to Add OH-W Wireless Smoke Detectors

    Not sure what your trying to do as it didn’t make much sense to me. 1. Enter engineering 2. Enter zone setup 3. Go to first free zone 4.press reset learning countdown starts 5.put the three batteries in the correct orientation What happens?
  4. secureiam

    Landline Query

    If your number hasn’t been reallocated you could ask your service provider if it’s possible. Chances are a new line will be digital but again you need to ask the provider.
  5. secureiam

    Texecom Premier Elite 24

    show wiring but sounds like arming mode is E/E and you haven't activated the exit door and closed it
  6. secureiam

    Texecom Premier Elite 24

    If not using wintex, engineers code, zone setup. You can program the zone there
  7. secureiam

    Texecom Premier Elite 24

    white and green back at the zone. zone programming needs checking and wiring type set to TEOL
  8. secureiam

    Texecom Premier Elite 24

    Programming is TEOL. For the anti masking although unless there is a fault it will work on double pole just won’t report correctly. Can’t see the wiring so clearly on my phone where I am now. Withe lid secured properly. What’s is saying in zone status ?
  9. secureiam

    Scantronic 8136 uk Keypad protocol

    https://www.eaton.com/gb/en-gb/support/download-center.html
  10. secureiam

    Scantronic 8136 uk Keypad protocol

    Scantronic Eaton
  11. secureiam

    Texecom Premier Elite 24

    not walking testing ? any errors in day mode? Have the zones in use been programmed correctly or not at all? at default the arming mode is E/E this requires the the e/e zone to active and then secured, this should be a door contact and usually on zone 1.
  12. secureiam

    Bell Box Advice - Flashguard vs Orisec ES-330 vs Pyronix Deltabell X vs Texecom Odyssey X-B

    I wnet through the LEd issue when i was at Orisec and was sat in a room looking at several different bells with there leds on, they are clear and perfectly adequate to be seen in daylight. WRT to the tamper making it brighter that because effectively more current is being run through one LED.
  13. secureiam

    What can I use

    Alas modern tech are sensitive soles
  14. secureiam

    What can I use

    The logs the fault shows up and restores duration 40 seconds. A battery test is 10 seconds long but doesn’t show in the log, but occurs every 24 hours, the times are close enough to consider it’s something happening after x hours roughly 24+. The fault could be caused by power dipping below...
  15. secureiam

    What can I use

    Yeah have them as standard they do a nice little kit with several filters and earth choke. When installing the checks are done and installed. It was a take over and the original PSU wasn’t monitored originally. When it was replaced with a mointored PSU within a week it picked up issues with...
  16. secureiam

    Can you recommend a fall alarm?

    Aware if a few that use this, it can track if they go off wondering, it can be used to talk to them. A family member uses one, it’s with them wherever they go and literally asks if your okay and if you need help if you don’t answer it calls it for you anyway
  17. secureiam

    Can you recommend a fall alarm?

    it makes a call if you don’t cancel it after an incident.
  18. secureiam

    What can I use

    didnt see frequency on this device, I know spikes and frequency changes can cause PSU's some issues.
  19. secureiam

    What can I use

    I am aware there has been issue to this building in the past, which have been sorted allegedly, I have dug deeper remotely and now have a chain of events leading up to this problems which is almost certainly the start of the chain reaction, just hasn't recovered like the rest of the system, so...