  1. sparkymarka

    Help needed setting up CCTV cameras

    It’s not that camera ….
  2. sparkymarka

    Help needed setting up CCTV cameras

    Read the spec sheet I posted …it does support a memory card …you would have to connect that camera to the your network to access the card and set it up …that bnc video output is only probably to assist setting up the camera
  3. sparkymarka

    Recurring COM4 Communication Fault on Honeywell Galaxy GD96 (Need Help)

    This may a long shot ….as you are using SIA format …does it transmit text description to the ARC ? if so are there any non SIA text in any of the descriptors , I’ve had with panels if you put say a / in , it locks up the communications ( dual com ) …
  4. sparkymarka

    Are these old bulkhead light fittings replaceable with LED?

    I take you don’t get out much ….seen loads of these fittings around the uk ..
  5. sparkymarka

    Premier Elite 64 w - factory reset

    I think ( as I don’t really do wireless on the texecom ) you go to device and press “ reset reset “ to delete it ( off top of my head )
  6. sparkymarka

    Premier Elite 64 w - factory reset

    Onto keypad and check zones are all the descriptors back in the panel , exit engineer and check that your original codes are in …
  7. sparkymarka

    Scantronic 9800 output

    Fit relay 12v dc handy little relay or Paxton relay …12+ to one side of coil the other to bell trigger …
  8. sparkymarka

    Premier Elite 64 w - factory reset

    Put into engineering Remove lid Put com lead on com2 Open wintex …choose saved ( original profile ) , select connect by pc com ….does it connect ? It should say at the bottom screen , if not what warnings does it com with ? Check that the UDL is 1234 ( default in wintex ) at the panel in UDL...
  9. sparkymarka

    Premier Elite 64 w - factory reset

    Ok ….if it’s defaulted you need to put in the UDL code or it won’t let you download the wintex profile ….what does it say on wintex when you try to connect to panel….also what com port are you plugging onto ? Com1 or Com 2
  10. sparkymarka

    Premier Elite 64 w - factory reset

    I can’t see how you have caused this by making one zone not used ? ….what else did you do ? …anyway just reload your profile from wintex it should be ok
  11. sparkymarka

    GDX5 handset flashing red and not working after power outage .

    do other people in your block have the same fault ?
  12. sparkymarka

    Optima compact beep warning sounder

    Press chime then 0 …
  13. sparkymarka

    Help needed setting up CCTV cameras

    FFS ….if he can’t get it working on a short bit of cable to a video input …then what’s the chance he can sort it via the IP route …which has many other sidelines / settings to sort
  14. sparkymarka

    Help needed setting up CCTV cameras

    Where do you live ?
  15. sparkymarka

    Optima compact beep warning sounder

    What devices do you have ?
  16. sparkymarka

    De-commission Paragon Super II

    Don’t think so maybe the 030 version or possibly the dummy version with a sounder inside
  17. sparkymarka

    Help needed setting up CCTV cameras

    I take it you didn’t bother to read all the thread ? It’s allready been said and it looks like the poster has allready bodged up a lead to connect it !
  18. sparkymarka

    De-commission Paragon Super II

    Problem is …. They did 4 versions Prima 100 no cut off Prima 200 no cut off Prima 300 ….with cut off Prima 500….with cut off ….normally green LEDS Plus a Prima 030 ….single LED ( so it’s not that one ) I would wait till midday then power it down mains and battery and see if the sounder cuts...