  1. ebee

    Plug in solar

    Certainly some folk do that, you can trick some of the people some of the time and that amounts to loadsa money so the ad industry has loadsa money. If you look back at some things sold as the best 20,30,40 or more years ago and that every so often the made a new improved one then that must...
  2. ebee

    Interesting Regulation of Yesteryear

    A nice "Fudge" of notation of nominal declared voltage!
  3. ebee

    Protector-Plug Flymo

    Eric, just to clarify, with the lead I mentioned the E from the circuit being utilised fro the installtion itself is not connected to anything in the lead at all. A "Fake Earth" is employed from the household N in the socket. The RCD under test sees an N and an L and another N at its earth...
  4. ebee

    Replacing back garden light - would you choose light with PIR sensor?

    All valid points. When the Tungsten Halogen tubes were the normal on some I would try and make the ON time 3mins minimum to assist longevity of the lamps, similarly the old bog standard filament lamps did not enjoy the stress. much either, in fact fluorescents did not appreciate lots of...
  5. ebee

    Interesting Regulation of Yesteryear

    Named after someone named Michael but not sure what his last name was.
  6. ebee

    Replacing back garden light - would you choose light with PIR sensor?

    Originally some were British made apparently and had a decent arm length and good adjustment. Then came along combined/closely coupled cheap units and the prices raced down. Personally if using PIR switching I prefer seperate sensor an lighting - Why? because you usually need the light to light...
  7. ebee

    Protector-Plug Flymo

    I`ve just edited post number #14 - hopefully I`ve finally cleared it up!
  8. ebee

    Protector-Plug Flymo

    The N at the socket is derived from N at the plugtop. The E at the socket is derived from the N at the plugtop. The L at the socket is derived from the L at the plugtop. Therefore any fault at the socket is seen as a N L current at the extension plugtop only and will not trip the circuit RCD ...
  9. ebee

    Protector-Plug Flymo

    Well would a one in one out socket/plug need a fuse - some of those two way splitter type death cubes have no fuse. The esy way to test it on an RCD socket is to get a plug and wire N on plug to both N & E on a test extenion type socket outlet and the L plug to L socket - sometimes known as...
  10. ebee

    Protector-Plug Flymo

    Depending upon age it might be better than a lot of modern stuff.
  11. ebee

    Plug in solar

    The reason I mentioned a formula and perhaps an app or something is a slight mod on one of my modes of thinking after many years of being self employed. In brief, one of my main inclinations would be - will it save me work/money/both and to what extent? Simply put as a quick rule of thumb the...
  12. ebee

    Mains tripping

    not really true then.sometimes does but sometimes doesn`,?
  13. ebee

    Plug in solar

    yes indeed Eric so another facet of the change of the numerics in the equation too so once the rules have reasonably settled some way then the initial cost of purchase and the costs of the tarrifs are two main items in actual quantity that may vary in the equation. writing a short computer...
  14. ebee

    Protector-Plug Flymo

    Hiya Eric = no sign of a test button? What I might have been tempted to have tried is the old tried and tested "Bang Bang 240 Test" as we used to call it . a 8200 ohm resistor of highest wattage to hand wired across L & E pins of a spare plugtop including a 1A fuse as a Go/No Go test...
  15. ebee

    Plug in solar

    So it`s not looking portable and cheap but more like portable and expensive for a kick off. Probably perceivable that some might still save though but it`s up to the individual to calculate before buying, Some might still rush in without calculating though and look at the adverts thru rose...
  16. ebee

    Instructions, should they be required, what should they say, etc.

    Sorry yes, it was a question and he answered clearly not. Thats me told. I do not know why some would think it is allowed but clearly not Eric though!
  17. ebee

    Extremely loud bang near fusebox.

    I investigate reports of such a bang a few years back, after the customer told me where he thought the noise came from I looked under floorboards. T & E hanging down under the floor and laying on damp soil. Pinhole in cable (might have been there since installation some years previous). I...
  18. ebee

    Instructions, should they be required, what should they say, etc.

    I can not work out how you think oversleeving of g/y cables is allowed in the regs.
  19. ebee

    L-ion battery issue

    You were asking if they are going to report it! I was asking if you were going to report it. (A rhetorical question).
  20. ebee

    Plug in solar

    It depends what the instructions or the rules say about the type of plug or its properties - lets wait and see then pick holes in it!