Search results

  1. R

    1st fix for tv

    Just realised that my picture in the post as been cropped!! tthe key to the cables is Orange = 2 core coax (shotgun cable) (1 line equals 2core cable) blue= cat 5 data cable
  2. R

    1st fix for tv

    Hi I am renovating a house and have put 1st fix cables in as the diagram below i have a last chance before plasterer is to cover them over is there anything wrong with this layout? i am not certain what subscription (freeview, sky) tv i will eventually have, i just want make sure i have...
  3. Untitled

    Untitled

  4. tv point

    tv point

  5. R

    Structural glass

    Think weve cracked it! Glass people are advising a 25mm rebate in the frame and the glass will need a 6mm clearance giving a bearing of 19mm on all edges, the rebate will be taken up with a 6mm rubber gasket and the glass will sit on a 3mm gasket. Just for those who may be interested price...
  6. R

    Structural glass

    Hope this may be posted and will get some decent feedback. Currently doing a small project in deepest wales, my client is one of the architectual team who designed the gherkin no less!! as part of the works there is a glass landing area which is approx 1800 x 900mm which ultimately sits in...
  7. R

    The right thing

    Not sure why I am posting this, but I just thought i would share for the hell of it!! Many years ago i worked for a company who provided Modular solutions to schools for additional classrooms etc, the company was fledgling and trying hard to become a market leader (it now is!! Built off...
  8. R

    rendering Chimmey

    Hi to everyone I hope the forum collective can advise me here?? Am presently renovating my house, i have a good skill level in most things construction, this will be my fourth renovation, plus i work in industry. I am just asking for a few tips tho regarding my chimmey stack on present...
  9. R

    Seemingly Lawless

    there is no sense to this post other than 2 different individuals at different ends of the social scale are very similar in that they are putting two fingers up to building control with what i can see very little repercushion!
  10. R

    Seemingly Lawless

    Just thought i would post a bit of a rant a bit of a story of building matters that i am involved and aware of. 1. My neighbour (i live in a semi dtached small holding were my neighbour as identical but mirrored 1940s house) I am currently building a two storey extension, with my help my...
  11. R

    Joist Spacing

    Right ok have had a total rethink on this. Have decided to turn joists 90 degrees so that the total span is 3800mm I will have one truss bolted to wall and use joist hangers, the other end will bear on new blockwork, total span will be reduced by 50mm to 3750mm. I have inherited as...
  12. R

    Joist Spacing

    Slightly confused now as 1st reply said they would deflect whatever c/c I see that tables are realtively easy to find, but cannot find my answer! Russell
  13. R

    Joist Spacing

    May be better to ask the forum what is my maximum span for a joist this section (178 x 50mm) I can reduce spacings to whatever i want if it gives me a better span. All help much appreciated!! Russell
  14. R

    Joist Spacing

    Unfortunately I have to make them work What C/C anyone Know. Rusell
  15. R

    Joist Spacing

    Mornin All I am building an extension and wish to try and determine my floor joist options. Firstly the joist serction size is to 178 x 50mm (these I already have from a demolition job i done some time ago, (they are 6 meteres long and i have plenty of them.) I have a single span of 4,5...
  16. R

    cable

    Hi all couple of questions that may be answered here regarding sky installation I am planning ahead and are refurbishing house, I want TV in Living room, kitchen, main bedroom. I plan to run WF shotgun cable from each position to external wall were ultimately dish will sit, Heres the...
  17. R

    Smoke detectors

    thankyou Jeds This seems to be the answer Thanks Russell
  18. R

    Smoke detectors

    Can somebody advise me please Am extending and knocking about my house and want to add mains smoke detection , I would like to put detector at GF hall /stairwell, FF lkanding, and in new extended kitchen, I believe from a Building control point of view I am only deemed to put Smoke detector...
  19. R

    Steel beams

    Sorry Noseall but youre "stuck" Im not after liability i am after calculations! I am fully versed in all the construction detail and suspect my serial size will suffice all the parameters, just need the correct maths (which dosent lie), its a self build the liability rests with me to construct...
  20. R

    Steel beams

    Are there any charitable structural engineers (or even otherwise but capable) who may help me with my steel beam selection for creating a knock through. I am pretty well knowledgable about building, building control, and even could at one time do these calculations (hnc structural design)...
Back