  1. C

    Vaillant TurboMax Problem - Help please.

    with the heating off,run the hot tap and see if the central heating flow pipe gets hot,if it does its a definate new diverter valve req which sounds wot the fault is,i have no idea why he changed heat exchanger cos its nothing 2 do with ure fault,waste of money...
  2. C

    quote for replacing motorised valve

    the bg engineers get 70 mins for each completed breakdown??hows that not true??obviously if it takes longer it does take longer :?
  3. C

    quote for replacing motorised valve

    the gas board get 70 mins to do any breakdown apart from cylinders etc etc,plenty of time to do an awkward 2 port..... :lol: :lol: :lol: :lol:
  4. C

    quote for replacing motorised valve

    here briefly u need to vent ure anger elsewhere mate,i think the VERBAL quote is overpriced based on he hasnt assesed job.and "the trace and repair prv" is comical. :roll: :roll:
  5. C

    Baxi Combi 105e

    New pcb req'd m8,after aps,fan venturis confirmed ok.the fan relay on the pcb stick after time
  6. C

    quote for replacing motorised valve

    Lol,i didnt mean to annoy anybody and to be fair 'rip off' was the wrong word to use,maybe overpriced would have been better.as for 'wot boiler it is for the prv' he clearly states its a profile so its gonna have an external exp vessel and prv.my comment was based on the fact it is a pressurised...
  7. C

    quote for replacing motorised valve

    Blocked cold feed???its a pressurised system!other than the 2port being behind the cylinder theres no reason why it cant b done in 2hrs and drink a cup of tea afterwards.65 pound an hour!!?? British gas charge 70 quid an hour!
  8. C

    quote for replacing motorised valve

    Rip off,ure looking at 75 quid max for parts,so hes charging 200 quid labour for a job that even if its awkward shouldnt take any longer than 2-3 hours max
  9. C

    quote for replacing motorised valve

    its £40 ish for a good motorised valve + labour
  10. C

    Powermax.

    you mean the powerma HE?? PRV-5106288 EXP VESSEL-5106287
  11. C

    Glow worm 30ci no DHW but CH ok

    thats correct but ive also had f9 when the thermistor was out of range.get an rgi to have a look
  12. C

    vaillant vcw 242 EH not working on central heating

    when u say the diverter moves in fully does it definately activate both microswitches??they can become lazy and just operate bottom switch.
  13. C

    conventional boiler -some radiators heat when set to HW only

    look on the ch flow pipe near boiler,it will be 22mm pipe,u may have a brass valve fitted,difficult to say wot it looks like but it will be a compression fitting and it may have an arrow on it idicating the flow.either way as uve got a gravity system a non-return valve will need fitting,cheap...
  14. C

    Upstairs radiators won't fill with water

    if u bleed the rad and no air or water comes out then its more likely blocked cold feed,quick check 2 confirm this would be to attach hose as if ure going to drain system,open draincock up then jump in loft 2 see if the small header tank is filling,if it isnt its a definate blocked cold feed
  15. C

    conventional boiler -some radiators heat when set to HW only

    do u have motorised valves that control ure ch and hw anywhere on the system??if so it will be one of them passing.if u dont have them uve got a gravity system which will need the non-return valve replacing if it has 1 or a new 1 fitting 2 system :)
  16. C

    Baxi 105e combi flame keeps going out.

    my opologies,just remembered it was the hw 1 i changed!!
  17. C

    One radiator doesn't heat . .

    sounds like the thermostat is stuck,turn off both valves and remove rad,open up valves and see if pressure is there,also see if valve in trv hasnt got stuck
  18. C

    Baxi 105e combi flame keeps going out.

    correct me if im wrong but the last temp sensor i changed on 1 of these it was a wet pocket??
  19. C

    Albion Mainsflow faulty heat exchanger

    P.s I live in 1 of the hardest water areas in the country and scale doesnt effect combis like people make out,its Always sludge from ch thats blocks then.just fit a suitable scale protector that will HELP but not completely stop scale...HS38's are good and easy to install with no servicing req'd
  20. C

    Albion Mainsflow faulty heat exchanger

    Uve got 2 options,rip it out and put a descent unvented cylinder in,or just fit a combi,thats wot I would do :)