  1. C

    Powermax 155x - parts and repairs

    powell 30-not being funny mate but i work on powermax 155 and HE'S daily,when working wiv bg b4 i tried to arrange joint vist on powermax 155 10+ years old and baxi told me there and then WE WILL NOT DO JOINT VISITS ON ANY POWERMAX'S 10 YEARS OR OLDER.as for HE'S ive replaced van loads of...
  2. C

    Powermax 155x - parts and repairs

    bg are the only people to work on them,not even manufacturer will touch them now,parts are expensive and stuff like pumps are going on them which req long drawn out drain down and refills,anyone with one of these should be on contract or thinking of changing it when it goes................oh and...
  3. C

    Glow-worm 30 CI

    sounds like the plastic hydroblock has cracked.....ure looking at around £200+ in parts alone.not eaxactly the easiest part to replace and ure looking at 2-3hrs on top :cry:
  4. C

    My Potterton Profile 80e often doesn't start up

    this ones slightly baffling me.......other than its still air circulating in system and its air locking intermitantly.what is worrying tho is why theres know pump over run wired into the boiler,its a big 80e which req.s it as per manufacturers.if its -over heating after 18 odd minutes the...
  5. C

    My Potterton Profile 80e often doesn't start up

    after fully reading ure last reply i would say its either blocked cold feed,circulation issue pump etc,if u can hear trickling around boiler its when the system is not completely full,as previously mentioned it could be something as easy as a stuck ball valve in ure header tank.another simple...
  6. C

    My Potterton Profile 80e often doesn't start up

    forgot to ask,u said it o-heated after 18 mins????do all of ure rads get at least warm at this stage????if they are all getting warm then it cant be a circulation issue,do u find downstair rads poor??
  7. C

    My Potterton Profile 80e often doesn't start up

    the question regarding o-heat stat........its a manual resetable stat,these do not automatly "make" when the system cools,u physically have to reset it.its just a type of stat.if its a blockage in the system normally the boiler would bang and clatter within 20-30 secs,if its not doing that i...
  8. C

    radiators go cold with ch and hw switched on

    do u have 2 motorised valves controlling ch and hw??
  9. C

    My Potterton Profile 80e often doesn't start up

    forgot 2 say ure bypass should be a gate valve with a red handle situated in airing cupboard tee'd off before flow into the motorised valve/valves
  10. C

    My Potterton Profile 80e often doesn't start up

    wot u need 2 do is get the boiler working by pressing the rest button,stand and waite while its running,is there any gurglying noises??if so it may be air in system causing boiler to overheat??does the flow pipe get red hot after being on for only 20-30 secs???if so this would suggest...
  11. C

    Diverter Valve Problem?

    dont waste money greasing,repairing the inners,it would last a maximum of 3-4weeks.get the guts changed,its a strightforward job anyway
  12. C

    boiler flue

    depends on the distance the manufacturer gives for opposing boundaries,i would check that out first
  13. C

    honeywell y plan diverter valve

    Yeah the synchron motor is knackered
  14. C

    My Potterton Profile 80e often doesn't start up

    That reset button is the over heat stat tripping so its overheating for some reason and can do this for many reasons.is the bypass open??the boiler stat should never b on max cos they had problems wiv o-heating wen on max,is pump over run working?is there still sludge in system?first u need to...
  15. C

    Pilot Light won't start on Myson Marathon 80c Boiler

    Can u see a spark through pilot window when u try 2 ignite it?if u can pilot lite is probably blocked.at this age the igniter could b knackered,in any scenario a rgi is req'd tho,cheap job anyway
  16. C

    Jaguar combi HW problem

    if uve had 2x heat exch in the last year and not had system flushed out its more likely blocked plate/plate again,get it flushed then change plate
  17. C

    Powermax 155x - parts and repairs

    What ballox would that be then?
  18. C

    Potterton EP2000 Programmer replacement

    Yes ure system is fully pumped,not sure whethe exactly straight swap but would b easy 2 change neway,make a note of the live,neutral and earth connections then u should have hot water off wire,hot water on wire and central heating on wire.wiring diagram will b on back of programmer.just note the...
  19. C

    Powermax 155x - parts and repairs

    fitting second hand spares to a powermax????????????????????? :twisted: :twisted: thats crazy!!
  20. C

    BG Strike

    bg wouldnt last if they employed shed loads of contractors????????why would a customer pay for a premium service if there getting contractors 2 do the work??they mite as well just ring a contractor in first place??