  1. G

    PSI/Bar of an expansion vessel

    Typically 0.8 Bar for a standard install ie. boiler not in the basement and several floors above (that would preclude a higher pressure)). Check pressure with zero pressure on the water side of the vessel. Be amazed if that vessel's still ok....but they were tough boilers given most were illegal...
  2. 20250805_161434.jpg

    20250805_161434.jpg

    Flexible cables
  3. 20250721_135622.jpg

    20250721_135622.jpg

    Leaky alkalines
  4. G

    Home working, what are the rules, pro, cons, etc?

    I suggest you check whether you can get your buildings & contents insurance to cover it....anything apart from a purely admin role and it's almost impossible to find a suitable policy. There have been many articles published over the last few years looking into this hurdle, estimating that...
  5. G

    Isolate Worcester bosh boiler leaking

    Turn the boiler power off at the wall. A common leak is the LHS plastic manifold pin holing. The 2nd pipe (15mm) along from the RHS...follow it up into the boiler and turn the isolating valve 90 degrees. Hopefully that will stop it. Don't use the hot taps.
  6. G

    Baxi sparking on flame sensor - Engineer refuses to call Baxi

    The trade's full of incompetence...the earth lead and spark symbol next to the electrode are more than enough to get it right, let alone the manual and shape of the electrodes.
  7. G

    Baxi sparking on flame sensor - Engineer refuses to call Baxi

    If this is a Megaflo 2 GA then indeed the electrodes are swapped. However, this model has the dire gas adaptive system (it constantly monitors the gas/air mix using the flame sense electrode). It will be very confused as the flame current will be different between ignition & spark...
  8. G

    Vibration noise, any ideas pmease

    WC flush valve leaking?
  9. G

    Yorkshire Street elbow solder query

    It depends if you're the typical diyer that spends an hour heating the joints but you could wrap a wet rag around the street elbow joint. With pump pliers gently crimp the end of the fittings so they grip the pipe...you can then pre-fab and solder the lot in one go. Offsets look a lot nicer with...
  10. G

    Volvo S60 D4 2013 AC not working

    As the scan live data is showing a pressure reading the AC system has an analog output sensor (and not a simple trinary switch) so don't go shorting out pins. Hope you didn't waste time with those diy cans...the refrigerant charge needs to be the appropriate amount for tge vehicle. We pressure...
  11. G

    Extreme limescale in shower bar

    It looks like the classic baffle problem. Do a forum search snd you'll find numerous postings going back 6 or 7 years showing pics.
  12. G

    thermal goo

    Given the lack of screws on those FETS it does look like a simple mechanical bonding rather than proper heatsinking. Use Dowsil 744, it's an electronics grade silicon that only releases non corrosive alcohol solvents during cure...
  13. G

    Chimney Pots and Cowls

    What are building control charging you to get the install/flue work checked and signed off by a Hetas installer, although any installer is mad to sign off others work (when they can't really see properly whats been done), in the gas trade it's banned. This could all come back when you sell the...
  14. G

    Chimney Pots and Cowls

    Normally any flue work either remedial or new is notifiable work to the local authority under the building regs. You must be either Gas-Safe or Hetas registered to self certify your work. A roofer (or builder) will not have the knowledge or qualifications to do so...and the qualifty of the...
  15. G

    Compression fittings with no play in pipes

    Google compression slip coupling...these fittings don't have a centre stop. The longer version is sold as a repair coupling.
  16. G

    Greenstar 24ri - large temperature drop before re-fire

    You shouldn't need to run the pump on speed 3 especially since the boiler is designed to run with a more favourable 15 to 20 degree drop. Since the the heating side appears to function as expected (although it is only really tested when outside temperatures are down to zero) I wonder if the...
  17. G

    Greenstar 24ri - large temperature drop before re-fire

    Is this an old cylinder with the primary coil designed for gravity circulation from the boiler? With 28mm primaries it would suggest so.
  18. G

    Fitting PRV on cold water bathroom pipe

    Connect your bathroom feed etc. to that capped 22mm pipe on the pressure reducing valve. Has the installer filled in the benchmark logbook and notified the install? You should get a building regs. compliance certificate. Pipework should be lagged...where's the expansion vessel?
  19. G

    Can you have a look at my lawnmower engine?

    Have a look at this Quantum engine throttle plate...looks like you've bent the the spring pivot...
  20. G

    Vaillant Turbomax 282e diaphragm

    There are a few other boiler checks that need looking at including airflow..and unfortunately it's beyond diy.