  1. jeff the gasman

    Quality of plastering workmanship advice?

    The telltale sign is when they’re mixing the plaster with a white stick!
  2. jeff the gasman

    Hive help

    Just wire to 3 and 4 in the boiler from 1 and 3 in the stat. Don’t forget to connect the mains.
  3. jeff the gasman

    Hive help

    Oh dear!
  4. jeff the gasman

    Confused about sizes

    If you’ve got a combi you’re wasting your time.
  5. jeff the gasman

    JG Aura 230v Thermostats call for heat at midnight for 5 minutes!

    To be honest I think it’s a software glitch or a pump exercise programme! Setting a separate one channel programmer to kill the switched live would cure the issue. Or get hold of their rep. And ask him/her/it.
  6. jeff the gasman

    B11 oil burner troubleshooting

    Is it sparking? Check coil resistance!
  7. jeff the gasman

    Thermo-syphon

    https://dolantethole.wordpress.com/2013/01/30/anti-gravity-valves/
  8. jeff the gasman

    Odd whooshing noise

    The white silocone washer on the left. Or the complete valve. Look on fixthebog.co.uk for the same valve. If the existing washer has pimples, pop them with a pin and squash the water out until flat. https://plumbinbits.co.uk/product/fluidmaster-dual-flush-valve-pro820uk/
  9. jeff the gasman

    Expansion vessel failure

    It’s much the same as tyres deflating when a car isn’t being used. Think it’s called Graham’s law of absorption or something similar.
  10. jeff the gasman

    Chrome stain

    Denture cleaner.
  11. jeff the gasman

    Sewer smells

    You may have been the only house on a run with an open vent prior to new stack. Waterless trap is the way forward and does work. They were invented for crap plumbing technique rectification! Say no more!
  12. jeff the gasman

    Heating and hot water on at the same time

    If you trust a smart meter then DON’T. Take meter readings instead. Then study pure mathematics to doctorate level and work it out yourself. Smart meters are not smart! They always favour the supplier. Imo.
  13. jeff the gasman

    Expansion vessel failure

    You may also have a faulty secondary heat exchanger if the pressure rises overnight. Also a faulty filling loop. Get it diagnosed by a third party engineer. The guy who did the safety check only did a safety check. If you didn’t employ that person you have no recourse with them. Just get it...
  14. jeff the gasman

    Replace old room thermostat with Honeywell t4 in a W-Plan system

    Just wire to terminals 1 and 3 and safely terminate the neutral. Set controller to heating constant an hot water timed.
  15. jeff the gasman

    Removing Sludge with MagnaClean

    I’d get someone to diagnose the fault before committing yourself to fruitless attempts of curing the problem. Could just be down to lack of circulation causing it. Weak pump , motorised valve malfunction etc. Is the system noisier than usual? I come across systems piped in plastic with metal...
  16. jeff the gasman

    Tried everything but luke warm radiators

    Weak pump or bypass stuck open having looked at schematic drawing.
  17. jeff the gasman

    Tried everything but luke warm radiators

    Flow and return temperature at Boiler?