  1. W

    Lockshield valve hot, Radiator cold

    Thanks for your replies. I pushed down on the TRV pin and that moves freely, also opened up lock shield fully, but no luck. Do you think sludge is causing a restriction in the flow?
  2. W

    Lockshield valve hot, Radiator cold

    Don't know if anyone can advise what to do. Have two radiators which will not heat up, the lock shield valves are hot but the rads are cold. The TRVs are bi-directional Danfoss units and have been turned up for max heat. All other rads in the house work ok. I have also gone through the process...
  3. W

    Bosch dishwasher - no heating - pcb?

    Just gone to have another look and now I have no fecking water in the thing at all! A continuous whirring noise and the check water light on... But no water coming out...
  4. W

    Bosch dishwasher - no heating - pcb?

    Have the above a Classix model I think. Noticed recently that there is no hot water during cycle, this is a cold water supply only model. I read that the biggest issue with these is the heater relay behind the front panel failing. I checked the pcb where the relay is located, but it looks brand...
  5. W

    Baxi Solo HE18 lockout

    I wouldn't try to fix it myself, just wondered what the fault might be...
  6. W

    Baxi Solo HE18 lockout

    It was put in in 2007...
  7. W

    Baxi Solo HE18 lockout

    For about a year my boiler (baxi solo HE18) periodically locks out, works ok after resetting for another couple of weeks before doing again then again before reset doesn't work. Engineer comes out, cleans electrodes which seem pretty clean when he showed me and all works well again for 3-4...
  8. W

    Danfoss RX1 - 715si hot water issue?

    Just to say thanks for all your advice, much appreciated.
  9. W

    Danfoss RX1 - 715si hot water issue?

    The valve is an Danfoss HPA2. Is there anyway I could check the microswitch? Or is this a pro's only check? Thanks
  10. W

    Danfoss RX1 - 715si hot water issue?

    Thanks for this. I just turned the system back on and as usual the boiler fired up (timer showing as off) I then pushed the lever on the hot water actuator from Auto to Manual, the heating 'noise' in the airing cupboard got quieter but the boiler continued to stay on...? Is this what you would...
  11. W

    Danfoss RX1 - 715si hot water issue?

    Looks like I've got two of the top one... Do you think there's a problem with them?
  12. W

    Danfoss RX1 - 715si hot water issue?

    I hope someone can help me. Last night after a power cut the hot water seems to be permanently on. The timer unit 715si, appears to be working correctly, screen visible etc, and the central heating seems to work fine, i.e when the red light is on the rads warm up as they should and the...
  13. W

    Have caused a problem with my boiler? Baxi Solo HE

    Thought I would update in case anybody else finds this useful. I sorted the problem in the end, it was no big deal. After a bit of internet searching it appears I had not tightened the bolts holding on the combustion chamber cover sufficiently; this I have now done and all works well.
  14. W

    Have caused a problem with my boiler? Baxi Solo HE

    Hmmm... I realise I have made a mistake; so will get an engineer in to fix now. I was so careful when I opened up the combustion chamber though... Out of morbid curiosity, is there a formal procedure for accessing the combustion chamber? I guess its not the case of unscrewing it, taking it off...
  15. W

    Have caused a problem with my boiler? Baxi Solo HE

    You are correct I am outside my comfort zone; but the electrodes were oxidised and they have been cleaned; what would be the other 'rod' out of interest that resides next to the electrodes if not a temp sensor / thermostat? It just seems to be a bit of a coincidence that the overheat fault...
  16. W

    Have caused a problem with my boiler? Baxi Solo HE

    Recently had my boiler, a Baxi Solo HE serviced, as it kept cutting out, red lockout light on constantly. The boiler seemed to work ok for a period of time after that and then started doing it again. Last night even after pressing the reset button the boiler refused to start. SO in my infinite...
  17. W

    Baxi Solo 18HE keeps locking out.

    Hi thanks for the replies. Just checked the possible faults as indicated on the inside of the boiler flap. It states that if the red lock out light is flashing this indicates an overheat problem, if on constantly then its ignition. The red light is on constantly in my case, so I assume ignition...
  18. W

    Baxi Solo 18HE keeps locking out.

    I have a Baxi Solo 18HE boiler that over the past few weeks has been increasingly locking out (red light on) so that the reset button has to be pressed to fire the thing back up again, it is happening almose daily now. In the main, once the reset button has been pressed, the boiler will fire up...
  19. W

    Shared flat roof dormer with neighbour issue.

    As the title indicates, I have a flat roof dormer which is shared with the neighbour, due to a recent leak in the heavy rain I have decided to get it re-felted, but neighbour is not interested in getting his done at the same time. So I've got to get someone in to do just our side only. Question...
  20. W

    EPDM roofing costs

    Ok from the front aspect there are two dormers approx 2.5 X 1.5meters, back aspect one dormer 3 X 1.5m and lower flat roof extension 6 x 2.5m All felt covered at present, only the extension has a gutter, decking and upstands ok as far as I can tell Thanks