  1. vernerbongo2

    fire alarm activated, don't know why?

    I would need to check out all those details. I know most of the detectors are menvier , I will update this later on. Thanks in the mean time I was thinking of replacing a detector at a time with one that works to see what happens, there only are about 7 detectors.
  2. vernerbongo2

    fire alarm activated, don't know why?

    Hi guys, Have a fire alarm problem, fire alarm goes off falsely but the panel shows no faults. I checked all break glasses and all the detectors are not showing red lights as they would do in the area which caused the alarm. Anyone got an idea whats wrong and why it doesn't show up and...
  3. vernerbongo2

    seized water pump

    yes just looking at a website with those pumps. Thanks I will try it tomorrow :D
  4. vernerbongo2

    seized water pump

    the black plastic cover can be used to unsrew the bolt it covers. when you say pull forward do you mean pull it outward from the pump?
  5. vernerbongo2

    seized water pump

    Hi Have a seized water pump, (it hasn't been on for over a year) Normally you can take a cap off the end of it and free it with a flat screwdriver but this one seems to just have a screw in it, when loosened it doesn't seem to come out or do anything. Any ideas :idea: By the way I have...
  6. vernerbongo2

    tiger loop, is there an easier way to get oil upstairs?

    where would the non return valve be located and if there is none could I fit one? The feed pipe is 12mm copper, plastic coated.
  7. vernerbongo2

    tiger loop, is there an easier way to get oil upstairs?

    not sure if it has a non return valve because whole boiler is boxed into the kitchen. There seems to be no oil getting to the boiler, keeps locking out. I was told to keep turning it on til it fires up.
  8. vernerbongo2

    tiger loop, is there an easier way to get oil upstairs?

    Hi have an oil boiler upstairs and I ran out of oil.(which was refilled) It has a tiger loop and I assume I have to keep turning on and off the boiler lockout until the oil gets up to the boiler? Surely this is bad for the pump, is there another method?
  9. vernerbongo2

    texecom speech dialler

    I think maybe your right he didn't mention if he used one or not, he knows even less then me if thats possible :D
  10. vernerbongo2

    texecom speech dialler

    as I said its my brothers house, he also said when he had a phone plugged in upstairs he lost his internet connection downstairs but got it back when he unplugged the phone. Although both phones recieved and made calls :roll: I'l maybe call in and as you say try a couple of phones instead of...
  11. vernerbongo2

    texecom speech dialler

    Right that would be ok and it would give the dialler a wee bit more security which was one of my main concerns. Not sure how to overcome the problem were only one item works when more than one item is plugged in at the same time though, in the original post, I can't see why that would be. I...
  12. vernerbongo2

    texecom speech dialler

    It seems my extensions upstairs are linked in series with cat5 cable, so if I wire up the first extension cable at the master socket to the voice filtered terminals I can't plug in a pc upstairs or likewise if I wire to the unfiltered terminals I can plug in a pc but not a telephone? Whats...
  13. vernerbongo2

    texecom speech dialler

    I might try that but as I said I can't see why it won't work in the first place? Thanks, I have to go to work now unfortunately :roll:
  14. vernerbongo2

    texecom speech dialler

    Right been doing a bit of reading on adsl filter faceplates, of which I understand partly. Am I right in thinking if I install one, the extensions leading off to the upstairs won't be able to be used to plug in a pc to as it will be voice filtered only? I really need to plug the pc in upstairs...
  15. vernerbongo2

    texecom speech dialler

    no its a plain & simple double adaptor and I did as you said plugged the double adaptor into a single adsl filter, I already tried that, its a strange one. checked the phone socket wirring its ok unless its bt's wirring which is doubtfull. What way does a hard wired adsl filter work? Do the...
  16. vernerbongo2

    texecom speech dialler

    Hi professionals :shock: have a texecom speech/sms dialler, I just need to know what the bt sms service centre number is so it can send texts ? Also when the dialler and a phone are plugged in to a double phone adaptor only one phone makes and recieves calls the other does nout, why is...
  17. vernerbongo2

    Greenstar 27 HE Central Heating only warm

    Hi, don't know what you mean by flames cut out at 61! I'm assuming you would run it at 70 plus most of the time, I run mine at 70 all the time. :shock: Check room thermostat works and motorised valves work. if you have those?
  18. vernerbongo2

    heating

    Hi, you could connect the live wire from the central heating terminal to the hot water terminal in the mean time. It does mean you cant control heating and hot water seperately! Most programmers fit on to a single gang steel box sunk into the wall, if yours is like this then its a standard...
  19. vernerbongo2

    best type of silicone for a bath with a shower over it.

    Hi, I don't know where you would get that stuff? I have had problems with a shower cubicle seal between the tiles and shower tray. I have used cheap silicone £2-£3 and they gave way quickly, I then bought evo-stick batroom & shower silicone from b&q for about £6 and have had no problems since...