  1. Spark123

    Car battery resistance between the terminals

    As others have said, the internal resistance is calculated using a load tester. You must not connect a standard ohm meter across a battery, it certainly won't do the meter any good and could go bang. Normally something like this will do the job...
  2. Spark123

    Fabulous Old Theatre Transformer and Mercury Arc Rectifier

    Yep, asbestos was the in thing back then. The cloth covers on the back of those stills projectors will be asbestos, as likely the lining of the projection room to stop the spread of fire.
  3. Spark123

    Clarke DOL starter

    Thanks all, I have seen them on industrial sewing machines too! I have opted to go with a contactor variety from screwfix, about twice the price of the clarke variety.
  4. Spark123

    Clarke DOL starter

    Hi, just wondering if anyone has used these before: http://www.clarkeinternational.com/shop/range/details/direct-on-line-starters/path/accessories-consumables ? I'm wondering if they are a contactor or one of those spring switches? It says they are for single or 3 phase motors. I'm suspecting...
  5. Spark123

    What do the regs say about sockets fed from portable UPS being RCD Protected?

    Is the phase what gets pulled down due to voltage drop on that phase and the remaining two phases what get pulled up due to the two current return paths through each of the remaining two phases? The voltage will drop on whichever phase has more current drawn, this will in essence pull the...
  6. Spark123

    MK RCBO Recall

    I have added it to the sticky at the top
  7. Spark123

    REFERENCE - Useful manufacturer/product INFO

    MK have issued a recall for some of their B and C curve RCBOs CLICK HERE FOR DETAILS The recall notice states We have identified a potential safety issue with the manufacture of a limited number of MK Sentry RCBOs which may result in the device failing to trip under certain very limited...
  8. Spark123

    What do the regs say about sockets fed from portable UPS being RCD Protected?

    That is talking about a lost neutral, where you don't have ballanced loads on a 3 phase system and whichever phase is drawing the most current pulls the voltage down on that phase and up on the other two. When his happens magic smoke escapes from lots of equipment! In a single phase system a...
  9. Spark123

    Fused Spur for lighting

    Nope, they only make them with one switch. Options can be use a fused spur and the two gang switches, or use a grid system. Either way will not look as neat as what you had before.
  10. Spark123

    Confusing Contactors!

    Afaict the CAD32 comprises of 3x N/O contacts and 2x N/C contacts.
  11. Spark123

    Hive Multizone Self Install

    From what I remember a hive reciever requires a permanent live and neutral supply to it, when heat is called for it operates a dry relay contact. The earth connection is there for convenience. From what I gather your old honeywell timer/thermostat only has live and switch live? On the plus...
  12. Spark123

    Checking I Have Correct Electrics Setup for Electric Oven

    http://www.screwfix.com/p/mk-2-gang-45a-dp-cooker-switch-with-13a-switched-plug-socket-white/17157 http://www.screwfix.com/p/mk-2-gang-surface-pattress-box-white-44mm/19307
  13. Spark123

    Fused Spur for lighting

    You are correct to be concerned, if they removed the fuse spur and replaced it with a plain switch then your lights are now fused at 30-32A which is wrong.
  14. Spark123

    What do the regs say about sockets fed from portable UPS being RCD Protected?

    Will it be classed as IT (protection by ADS) or protection by electrical separation?
  15. Spark123

    Major wiring work on a house purchase, questions.

    That second bit is ancient, P2 was withdrawn ages ago.
  16. Spark123

    New socket for fridge freezer

    I'm lost!!
  17. Spark123

    Plug to Socket Extension with no Earth!

    TT supply?
  18. Spark123

    Which led batten for my garage

    If you want a good allround spread of light I'd stick with normal fluorescent.
  19. Spark123

    Connecting Two Routers To Fibre Modem

    You should be able to set the two up with different wifi names and passwords, so you can give the kids access to the second router and then turn it off at night. You want the two wifi signals on different channels, I like them at least 2 channels away.