Search results

  1. B

    Potterton condensing boiler

    Wiring to boiler/timer is not correct get the installer back...
  2. B

    Baxi Solo 2 50 PF replacement?

    Heateam WILL fix it
  3. B

    Baxi 105e - high pitch noise

    3 way valve o-rings.
  4. B

    Baxi Solo 2 50 PF replacement?

    Yeah seems odd to B.E.R as parts are available.....and simple to fix...this "vintage"stuff was designed to heat water and has done a pretty good job for many years.....before eco green lunacy and all that ****e....
  5. B

    Baxi 80e whining noise when hot water switched off

    Yes they do tend to "whine on " D.V Req
  6. B

    ticking noise in airing cupbard

    Must admit i thought about that but in these sensitive times using words like that anywhere is a no no thats why i opted for the mice...
  7. B

    Potterton Profile 80E boiler about to go ...

    Flame vitiation possibly due to inner flue corroded...
  8. B

    ticking noise in airing cupbard

    Mice playing tick 8)
  9. B

    Baxi Brazillia F8S taking too many attempts to ignite

    Is the symptom "it will not ignite atall" or does it light and will not "hold" its flame when the control knob is released ?
  10. B

    Baxi boiler sounds like it's pulsing

    Its got a pulse it lives it works RELAX its a BAXI !!!!!!!!!!
  11. B

    baxi bermuda inset 3 boiler

    What the post means is to insulate the ignition/rectification leads with electrode lead insulation sleeves in an attempt to stop the spark "tracking out " anywhere else. If this makes no sense to you do not ask any more gas related questions as i dont think you will get any answers.
  12. B

    baxi bermuda inset 3 boiler

    With double insulater :lol:
  13. B

    Baxi duo tec he24 CH but no hot water, no error code

    Yes correct sensor, the fault code will show if it is faulty not if it is out of calibration. Any way if we are all wrong its far cheaper than all the other parts you mention. :P
  14. B

    Plumbers on Watchdog now!

    I always thought it would be interesting to showcase the "customers" that refuse to pay and dispute issues etc."Rogue Buyers" :wink:
  15. B

    Baxi duo tec he24 CH but no hot water, no error code

    Change the dhw ntc thermister and it will work
  16. B

    Baxi Duo Tec wrong temperature reading for hot water

    Blocked plate heat exchanger.Remove clean out or replace
  17. B

    Potterton Combi Leaking?

    So no thickening of the plots then :lol:
  18. B

    Potterton Combi Leaking?

    So you where mistaken in thinking it was the condensate pipe dumping water it was actually the prv pipe.You need to empty the water out of the boiler [primary] you may aswell open the prv as it is probably fooked any way and attatch a foot pump to the schreader valve on the expantion vessel and...
  19. B

    Potterton Combi Leaking?

    So you where mistaken in thinking it was the condensate pipe dumping water it was actually the prv pipe.You need to empty the water out of the boiler [primary] you may aswell open the prv as it is probably fooked any way and attatch a foot pump to the schreader valve on the expantion vessel and...