  1. J

    Poor Shower Installation

    the plumbing is just as bad, why didn't he use the top entry and lose all those elbows. Re the cable to the switch, I know its shoddy but is it contravening anything with the outer jacket being removed but enclosed in trunking? bit like singles in conduit. (if thats what it is)
  2. J

    Floor socket

    I have floor boxes with sockets and cat 5 installed into tiled floors. As the cleaners dont tend to sling gallons of water around during a mopping session, water never makes it to the sockets. As far as I can tell, there is no greater hazard here than a floor box installed in a carpeted office.
  3. J

    Another gem on eBay

    just try buying it though...
  4. J

    Bosch WVT1260 not drying

    OK, before i shell out £140 on a new fan, im a little suspicious of the capacitor for the fan. there are two browns on one side and a single brown on the other. The side with two browns reads 240V and the single brown side reads about 76V How do I test the capacitor?
  5. J

    Another gem on eBay

    I cant see a problem with it either. how many 240V extension leads do you see with black flex, white flex, orange flex etc. B&Q also sell ext leads with yellow arctic flex fitted with BS1363 plugs.
  6. J

    Bosch WVT1260 not drying

    The thermostat had tripped but it seems to be because the fan wont run. I checked for voltage and got 240 on the brown, 0v on the blue and 240 on the black. Presumably this means the fan is at fault?
  7. J

    Bosch WVT1260 not drying

    Hi, Today my WVT1260GB has developed a fault in the drying cycle. The clothes are not drying or even warming. The machine doesnt seem to be making as much noise as i remember, a fan not on maybe? There are no error messages on the display Any ideas? thanks
  8. J

    Mem fuseboard

    Before I was responsible, someone fitted 3 630a MCCB boards in 300mm cable using the L1 Brown L2 Grey L3 Blue N Black. The covers were off for ages, I went spare, pointed it out and the solution? Fit the covers. Still like it today and its confusing, both in the board and the sub
  9. J

    Mem fuseboard

    well, there isnt a problem with one fuse blowing, just like using BS88s on a 3ph circuit. I see what you mean now, only one side of the centre tapped tx was fused :) MG do a two phase kit for their boards, is that what you used? the black dot often melts and falls out leaving a live...
  10. J

    Mem fuseboard

    are we talking DC here or AC? there isnt anything wrong with fusing both phases in that situation, or am I missing something?
  11. J

    Metal Halide High-Bays

    I have lots of sets of high-bays and all but one set have tubular fittings. there are sons which dont have safety glasses and some eliptical open rated MH lamps with safety glasses. I have seen special tubular lamps for low bays which dont need the safety glass but they can only be installed...
  12. J

    Metal Halide High-Bays

    Hi, I am trying to buy MH lamps for some fittings at work. I have obviously confused the local supplier because we currently have high bay fittings with tubular enclosed rated lamps fitted without safety glasses. The lamp is an Edison EDHPIT400, so basically, I need an open rated version...
  13. J

    New Eaton Memsheild 3

    I have never seen a board like that, usually go for MCCB boards. What is the biggest high load way you can use? is it 125A? Looks pretty neat anyway
  14. J

    Thermal overloads / oil filled contactors.

    that looks just like our powerhouse but ours isnt as clean :) flooded, full of who knows what, its sad really. Its hard to believe how they had mosaic floors and glazed brick walls, decorated better than modern offices
  15. J

    Thermal overloads / oil filled contactors.

    What date would you put on that? We have some similar stuff in our derelict powerhouse I thought it was DC stuff. sadly its all been vandalised. Seems a bit excessive for sp supplies. I think I have the remains of a mercury arc rectifier. Loads of wooden CT transformers too, Ill have a better...
  16. J

    11kv Circuit Breaker

    the n-e bond is in the switchroom just before the ACB in my installation oh, and we call it PNB
  17. J

    MPG

    astra 1.9CDTI 150BHP 8.3 seconds urban 39.2 hardly exclusive :)
  18. J

    There's your problem

    BV dotted all our sockets to show that their martindale tester had shown 3 amber neons. That must be good then :)
  19. J

    joining cables in dado trunking

    I thought as much, but the seed of doubt had been planted :) I hate chock blocks full stop, always find them at work from the smoke from them as they burn away
  20. J

    There's your problem

    thats a nice grain :) id be slightly concerned there but would guess its old. The green dot is probably to show that it has been PIRd in the past