  1. M

    1st fix

    Right.. Okay let me have a look
  2. M

    1st fix

    Just measured and I think it will be about 100mm from the block then he is putting insulation board in-between. Reason for the distance from the block is there are gas pipes along that wall ( Garage conversation )
  3. M

    1st fix

    Thank you John! I think they will be boarding further then a metal backbox would allow.. so it will be photos and measurements!
  4. M

    1st fix

    Probably a stupid question.. but builder is putting stud against breeze block then plastering. ( Needs to build it out slightly ) Thing is, how do I go about 1st fixing this as there will be no back boxes to leave my cables in? I'm training to be a spark.. and this is on my own house.. so I'm...
  5. M

    PIR light

    Yes came loose.. I've put that back in for the lights in the hall. That PIR cable is getting converted to a 1way switch for spots. And the PIR getting moved round the corner. I can leave it in a wago but it's driving me mad not knowing where it's fed from
  6. M

    PIR light

    Hi all.. Replaced old light with new.. and the new only needs a live and neutral. So there is a spare cable which is live.. I can't for the life of me find where it's connected! Driving me mad! Can you help? I just want to disconnect it. It is the far right switch in the pictures
  7. M

    Extending twin and earth

    So are you saying use good maintenance free junction boxes??
  8. M

    Extending twin and earth

    I saw that
  9. M

    Extending twin and earth

    Thanks everyone... I like the heat shrink idea, but I've got a few maintenance free JBs here.. as long as that's fine I'll go with that. The cable is up in the ceiling so heat shrink would be a pain..
  10. M

    Extending twin and earth

    Hi all, Trainee here.. just wanted to ask a question. Wall being knocked through and made into a door into the garage. There is a radial 2.5mm in the way and some 1.5mm lighting circuit. So I need to extend the cables to get them out the way. Am I okay jointing with a maintenance free JB...
  11. M

    Wiring for Shed

    Hi All.. I'm not able to pull the SWA for a few months now.. But before the builders start this week I do need to come out the CU and into a adaptable box outside for when I do. We are going with 6mm, so can I just use...
  12. M

    Wiring for Shed

    I think regardless, I will be coming through the wall direct to the CU.. just looked at the regs and there is no need for fire sealant, although I may use some anyway. I think I'll just use the double insulated SWA tails directly into the board rather than joint with the FP.
  13. M

    Wiring for Shed

    Hi, No the CU is in the garage.. but will be running it to the shed.. I did think of doing as you suggested, but with the CU being where it is, I thought I would add a designated circuit.
  14. M

    Wiring for Shed

    Good morning all.. Just wanted to ask for some advice. Running power to my shed from my consumer unit..(I know it is notifiable) I will be running 6mm armoured, so I come out of my CU with some 6mm FP I have and straight through the wall to the back of the house, I then use a JB to joint to...
  15. M

    No Power - Dishwasher

    How would I know?
  16. M

    No Power - Dishwasher

    That's what I thought.. thanks pal
  17. M

    No Power - Dishwasher

    Hi all, I have a S58T40X0GB/45 Neff Integral dishwasher. It stopped mid wash and now has no power.. Plug top is fine and is fuse and outlet. I wondered if it was an internal fuse, but after researching Neff don't have internal thermal fuses. If I'm correct, I need a new control board.. but...
  18. M

    Dripping Tap-stripped grub screw

    Anyone help with a tip to remove a stripped thread grub screw ? Its on a Franke mixer tap at the back and is a pain in the arse ! Everything just spins in it... Thanks
  19. M

    Panel Wallpaper

    Just stripped the old wallpaper.. and the previous guy who stripped the other wall paper has left scrapes all over the wall.. (Supposed professional) I have just filled with filler and will sand out.. it's a new build so the walls are pretty smooth.. Will I need lining paper?
  20. M

    Panel Wallpaper

    Hi all.. I have a wall 4300 long and have panel wall paper 530 in width.. so just over 8 lengths needed. Any advice as this wall paper has a panel pattern on it like below.. do I still start in the middle and add a little 50mm slither at the ends? Also I have some drywall filler that has...