  1. A

    ignition delay wb240

    Commissioning a boiler is the process of setting it up for safe use after installation. It would help if you let us know what boiler you have. Some makes do indeed wait a short while before switching back to central heating mode after being in hot water mode. If you stop running the hot tap...
  2. A

    Boiler electrics

    Most times I have found this to be a faulty pump or fan but it could be many things and really needs to be diagnosed by someone that knows what they're doing. You haven't noticed any water below the boiler suggesting an internal leak somewhere have you? Make sure you leave it switched off at the...
  3. A

    Replacing the gland on a ceramic hot tap

    I assume you mean the hot and cold tap cartridges as opposed to the glands. Ceramic cartridges don't even have glands. Just shut off your incoming mains and this will shut off both the hot and cold. Then replace the ceramic cartridges and turn the water back on. Running the hot tap will then...
  4. A

    Central Heating Room Thermostat Choice

    What boiler do you have? If it's a combi why don't you just fit the plug in mechanical timer and just a normal room stat as opposed to programmable. This way you can have as many on/offs as you want. Or just fit a honeywell cm927. Yeah it's programmable so slightly different to a normal on/off...
  5. A

    Combi max flow rate?

    You need a large unvented cylinder. You can barely run two showers simultaneously with a large combi.
  6. A

    Tips on removing plastic speedfit end cap from copper pipe.

    Push the cap onto the pipe more and then the collar should push back.
  7. A

    Help to Stop Waves

    Is the ball valve in the tank a proper brass style one with a ball on the end. I once saw a tank where someone had fitted a plastic torbeck valve designed for a toilet that was causing the same problems.
  8. A

    Overheating Baxi Solo 3PF Boiler

    I wouldn't be looking at a blockage if it takes up to 2 hours before overheating. I would be inclined to check the thermistors and the overheat stat. A cylinder doesn't take long to heat so when the water is on by itself the boiler may cut out when cylinder stat is satisfied before it overheats...
  9. A

    drinking from hot water system

    I can't see a problem with it other than i once read on a box of tea bags that it's best to use water that hasn't already been heated before boiling in a kettle.
  10. A

    Problem buying a new radiator. £80 for removal. Ouch.

    They're probably old imperial sized radiators. If you don't want to have to change the pipework I always go for the slightly shorter radiator and you can buy an extension that will fit between the radiator and the valve.
  11. A

    Making a Heatline Capriz

    I think this is officially the cheapest boiler on the market and for good reason. I can get them for £375 with a flue and timeclock. I heard of one instance where the heat exchanger and pump needed replacing. Once labour had been taken into account it was actually cheaper to just swap the...
  12. A

    Replacing toilet syphon help.

    You may need to replace the fixing plate between the cistern and pan as well as the donut washer. Can be impossible to get it water tight without doing so sometimes.
  13. A

    Re-route or extend boiler overflow pipe

    It clearly looks like a pressure relief pipe to me. In which case it can be extended to a new exterior position but it needs to have fall along its whole length so any water this is dispersed through the pipe can run away properly.
  14. A

    Is draining & refilling bad for the system

    It shouldn't be a problem. Just make sure you put inhibitor in when filling back up. It could be beneficial to add a cleaner the first time you fill up. You can then let this circulate with the heating on for a couple of weeks before draining again. At least this will help remove any dirt from...
  15. A

    Drained Central heating still has water in pipes

    Are some radiators on separate drops? If so they will need to be drained individually as obviously water isn't going to travel back up the pipes and find it's way to drain point on a different drop of pipework. Also you're brave putting isolating valves on to a heating system. Personally I never...
  16. A

    Vokera Boiler Problem

    Have you checked to see if water is escaping from the pressure relief pipe that should terminate externally, usually behind the boiler. Most likely when the boiler is operating and hot.
  17. A

    Another shower cartridge id

    It's not the one I thought it was actually. You'd do well to send your photos to lunns or the shower doctor. They'll help you.
  18. A

    Another shower cartridge id

    I'm pretty sure that's a crosswater cartridge. I'll have a look online and post the code for it if I find it.
  19. A

    Worcester Bosch 28i Junior Developed Leak

    The pipes have flanges on the end and sit flush against the manifold. Once you undo the nuts it will slide out.