  1. C

    European Plugs

    Evening gents, am currently involved in a large christmas lighting project. I'm renewing lighting harnesses that are attatched to street lighting colums. Sockets are already installed on the top of the colums, but they have european sockets on them?! They were installed around 4 years...
  2. C

    Box sinkers!

    Evening all! I'm a bit of a part time sparky and have been offered a rewire of a 3 bedroom semi, and have taken up the offer! Few questions - anyone got any recomendations for a box sinker? I usually use the hand method, but as i may have a fair few boxes to up from single to double i...
  3. C

    Shed CU

    I think it'd be bad practise to use a CEEform connector, such things are designed to be used in harsh enviroments, and if someone saw it they would likely presume it to be RCD protected. I'd stick with a 15a round pin.
  4. C

    TN-S or TN-C-S ? (with photo)

    looks like TNC-S to me. The earth is connected to the Neutral block
  5. C

    Strange looking socket...

    my grans flat built in 1990 was wired with singles in conduit... but the singles were blue GY and red! Blue and black wouldn't surprise me!
  6. C

    Outside garden lamp posts

    This is the question i sat in my CG2391.. looks like someones trying to get us to do their homework for them!
  7. C

    Extra consumer unit

    please delete
  8. C

    Napit or Not

    have just sent my application form of to napit, so i shall let you know what the process is like!
  9. C

    Pyro..

    just have the insulation resistance of the pyro checked, pyro lasts forever if installed properly.
  10. C

    SWA through wall

    split load doesn't have an effect. i think for this reason mk isolator terminals arn't labeled! I've got two MK CUs in my house both build in opposite ways, i wouldn't call the wiring of the CU cowboyish! What are you doing in terms of part p?
  11. C

    SWA through wall

    you can put an MK isolator on either side of the CU, i've done it before and it works fine!
  12. C

    DIY Jacuzzi

    i'd say you'd be better of just buying one, they'd probably be easier to maintain. we happen to own one, and the complexity of it is extreme, including things like an Ozone filter to kill bacteria. on a safety note the chemicals used in hottubs, like the Ozone stuff is very nasty indeed...
  13. C

    gorenje hob wiring

    sounds like its 3 phase......... does it say anything on the voltage plate? should say wattage, voltage ect ect
  14. C

    meter cable

    if its a new build why dont you just have the meter on the wall with the CU?
  15. C

    Joining the earth in 10mm t&e

    You can get 60amp choc bloc or you can get large crimps, but getting the tools would work out expensive
  16. C

    Wylex 3-way consumer unit Cat No 304

    kitchen fitters probably removed the electric meter!
  17. C

    Wylex 3-way consumer unit Cat No 304

    hang on, if its a fuse it shouldn't say b32 on it?! sounds like an mcb?
  18. C

    Circuit problems

    is there a fuse in the transformer? one of mine just blew and now I'm left in bloody darkness until i get a new one in the post! :cry:
  19. C

    Kitchen Downlights

    we have 9 in our kitchen, but its a very large kitchen with a high ceiling have fitted some in a bed room just by using loads of 20w, would say its the way to go!
  20. C

    Bonding Alkythene/plastic water service?

    your obessed.............