  1. T

    myson boiler

    if the actuator turns moves etc does this mean the actuator is ok ? i switch the cent heat on and the actuator arm moves to the correct position when i switch it off it returns. but the boiler does not kick in. same for the hot water. i have moved the arm manually but nothing. is it knackerd ?
  2. T

    myson boiler

    yes correct any tips had 3 actuators 1 pump 2 thermocouples 2 e2000 controllers. but has always worked or i always get it going any tips of whats wrong
  3. T

    myson boiler

    sorry i was thinking of the resonator on my car its the 3 way valve actuator that i mean
  4. T

    myson boiler

    its the 3 way actuator prob the 3rd one i have put in. it does turn when you work the controller
  5. T

    myson boiler

    hi guys boiler packed up again. same as last year control works 3 way resonator working. the contol asks for the burner to kick up on both the hot water and cent heat but it wont kick in. could it now be the gas valve ? thanks chris
  6. T

    sink

    hi the wife has just broke the sink (cleaning) need to get a new one. should i claim on my insurance (£60 excess) think the sink is approx £95. does it work like car insurance and my premium will go up ?
  7. T

    new boiler

    hi my myson boiler has packed in again, it is at least 25 years old so had my moneys worth. although over the years its had 3 3 way valves 2 controllers 4 thermocouples etc. now i carnt get it the main burner to ignite. so i wish to buy a direct replacment type boiler (so i can keep my cistern...
  8. T

    boiler not kicking in

    ok tried this morning, the boiler stat is working the controller is working. the boiler kicks up (noise like its on) but the boiler burner will not ignite. pilot light is lit thermo 3 way valve is turning (i canhear it) help please
  9. T

    boiler not kicking in

    sorry about that. ok its a myson economist boiler. the radiators where hot ok as normal but i noticed the bolier was not kicking in every so often as it usually does. today the wife said that the hot water was not very hot and when i try to turn the hot water or heating on the burner will not...
  10. T

    boiler not kicking in

    hi all. just noticed this week my boilers burner is not firing up. last night we had the central heating on and after a short time the rads where only warmish. i can here the thermostatic valve moving so thats ok. the controller is asking for hot water but the burner is not kicking up same as...
  11. T

    To hot?

    Hi. Had a brilliant innovation gas fire installed 4 months ago. On the lowest setting it is still to hot. Can it be turned down, the are 2 valves near the burner one is the shut off valve. Is the other a regulator?
  12. T

    3 way valve

    ok cheers so do you think the valve and actuator are ok ? this morning c/heating failed again. i need to push (help it) the manual arm on the side to get the heating to turn on. do you think it is the actuator?
  13. T

    3 way valve

    cheers yes i have removed the actuator and this turns when the c/heating is turned on. i have used wd40 on the spindle and it seems abit easier to turn with my fingers. this morning it worked ok as it always did just wondering with not using the c/heating as often as the hot water it has sort...
  14. T

    3 way valve

    i changed the valve cause of an electrical fault with it, the second time it seemed to have seized up ? OK I HAVE LOOKED AT THE ACTUTOR THIS WORKS AND TURNS WHEN THE CONTROLLER IS SWITCHED FROM HOT WATER TO CENT HEATING. THE VALVE HEAD MUST BE DODGY. I CAN TURN IT WITH MY FINGERS, JUST...
  15. T

    3 way valve

    hi, its that time again think the 3 way valve is stuck ? i have a oldish myson economist boiler with a potterton e2000 controller. we always use the controller as when we need hot water and cent heating. but when i try to switch the heatin on it doesnt turn on ( it did kick in after 3 hours)...
  16. T

    gas fire

    just a thought, would i be correct in saying the starter blocks are to low for a hole in the wall fire if the fire is fitted say 4 ft high. surely a builder or gas tech whoever could rebuild the starter blocks in a higher position on a sort of wall ?
  17. T

    gas fire

    cheers, i found this fire it says i has a precast flue option ? http://www.burningdesireuk.com/shop/class-2-precast-flues/precast-hole-in-the-wall-gas-fires/new-dawn.htm
  18. T

    gas fire

    thanks for the info. could it be possible to raise the starter blocks say 600mm approx say rebuild the bottom starter blocks to accomadate the fire at that height ?
  19. T

    gas fire

    got a few in mind they are the hole in the wall type sizes are approx 900 mm wide and 600mmhigh, the ones with a living flame. they all seam to be only for chimney or a balanced flue ?
  20. T

    gas fire

    hi. replacing my gas fire. i wish to fit a hole in wall type gas fire, but i have been told my precast flue is not ok for this type of fire. the flue is on a party wall. the fire will sit in asort of false chimney 300mm. so can the fire just have the duct coming out at 90 deg and connect with...