    Philips Master LED

    Hi, I have two Philips Master 7w LED Lamps for my bathroom... They say they don't require an LED driver as they have one built in and they will work with normal transformers. My problem is that even though they state this I cannot seem to get them to operate correctly with standard...
  2. W

    Earth Size

    They are 16mm from cutout to meter and then same from meter to consumer unit. The problem is that we have no henley block so the tails come direct from the meter to the consumer unit and this is sealed. I dont see how we are meant to have them replaced.
  3. W

    Earth Size

    Hi, I have been doing some work in my house and have removed some boards that were covering the meter tails as they need replacing. I noticed that I have 16mm tails along with a 16mm earth cable... is this a good or bad thing as I thought it was 16mm tails 10mm earth. Our DNO supplies the...
  4. W

    Consumer unit

    I wont be doing the work my self , im just getting an idea of the best boards to use as I dont want a crap one put in. I think the electrician I spoke to said to go for one that will allow all RCBOs.
  5. W

    Consumer unit

    Hi, Can anyone recomend a good quality consumer unit that is good for a sub board use in a commercial building? it can be either dual RCD or one for RCBOs. Metal would be good. Thanks
  6. W

    Floor socket

    Hi, When fitting a floor socket in to wooden laminate do you require a back box and if so what type is best? Thanks
  7. W

    Lower Voltage

    Hi, Light bulbs in my house blow every week (even CFLs) and i think this is due to the voltage been a bit too high for the bulbs (247-255v) I have contacted local electric board and they wont do anything so I was wondering if there is any way to transform the voltage down on the lighting...
  8. W

    Cooker connection help

    Hi, Buying a new cooker this week and it will draw a max of 3200w (from the instruction book) and says it should be "hard wired" My cooker feed is currently fed via 6mm cable on a 32A MCB, What is the best way to connect the oven? The cable also needs to supply the starter on my gas...
  9. W

    Low Voltage Downlights

    point taken :)
  10. W

    Low Voltage Downlights

    They are philips LED bulbs and say they work with normal transformers.
  11. W

    Meter Tails

    I went to a friends house the other day to see his new kitchen, in the process of this he has had a new CU fitted... the electrician has fitted new meter tails (blue, brown) in 25mm cable. The problem is that it is not the normal grey double insulated tails you see. Instead it is what looks like...
  12. W

    Low Voltage Downlights

    Hi, I have some low voltage downlights in my bathroom and I want to change the bulbs to LED (already purchased) to lower the running costs. One thing I dont understand though is that it says on my transformers that they take 0.26A on the pri side (about 50w) so does that mean that...
  13. W

    SWA Earth

    Yes I know... I was just telling you all what the SWA did etc so you could tell me if 4mm will be OK just to protect the armour.
  14. W

    SWA Earth

    The SWA is only for the cable protection and there is one core in all of them that provide the earth. They supply feeds to pumps and fridge controls, one is also a sub main to a small shead.
  15. W

    SWA Earth

    There is nothing bigger than 6mm SWA on my property but the last owbers did not earth the armour at either end... to save me buying differnt size earth cables can I do them all in 4mm? do you earth one end or both?
  16. W

    SWA Earth

    Hi, When earthing the armour in SWA what size should it be? do you earth it with 4mm cable? Thanks
  17. W

    Isolator Query

    It currently is: 16A MCB in CU--------1.5mm-------------FCU with 13amp fuse --------1.5mm SWA-------------Local Isolator------Pumps. But I want it to go: 16A MCB in CU--------1.5mm-------------1.5mm SWA-------------Local Isolator------Pumps. as the new pump control panel has MCB's...
  18. W

    Isolator Query

    So cable direct in to MCB (1.5mm on 16A MCB) and local isolator at panel is OK?
  19. W

    Isolator Query

    Their is an isolator next to the equiptment outside that is rated at IP66 but i just wondered if it would require on indoors also next to the CU as I have been told in the past never to use the MCB as an isolation device. When I say the fuse blows in the FCU i mean every now and then due to...
  20. W

    Isolator Query

    I currently have a SWA cable running outside powering two pumps and if there is ever a fault it blowes a 13A fuse in a fused spur. I want to get rid of this and wire it directly to its own MCB. My question is: there is already an isolator on the main control panel for the pumps outside but would...