  1. T

    xplelair sl100ht bathroom extractor fan

    No , not connected the switched live and the led that would be on if there was power to that terminal is off .
  2. T

    xplelair sl100ht bathroom extractor fan

    I have fitted the above fan and wired it just to permanent live and permanent neutral via a fused spur , I dont want the option to just pull a cord to turn it on as well , I just want it to operate on humidity . Since powering it up the fan is just staying on constantly , altering the two...
  3. T

    40 cdi loosing pressure

    The pressure relief pipe is not dripping , the condensate pipe is dripping as it should be
  4. T

    40 cdi loosing pressure

    Worcester 40 cdi is loosing pressure but has no leaks , if I fill the boiler to exactly 1.5 bar and then run the hot tap for 5 mins you can see the pressure gauge is loosing pressure , when it switches back to heating it has definately lost some pressure , is this going to be the DHW heat...
  5. T

    Central heating doesn't work after removing a radiator

    Cant see the radiator being removed being the problem . If all you did was shut off the valves then remove the rad then the pressure must have been low before , if when you try and fill it via the filling loop and you can hear water going in it must be going somewhere , check the expansion pipe...
  6. T

    Protherm 80EC pcb fault help

    Just to update all you helpfull guys , Turned out I had diagnosed the boiler fault correctly and all my testing was good , the main pcb that I replaced with a brand new one turned out to be a faulty board , returned that board to my supplier and they sent out another one and boiler fired up...
  7. T

    Protherm 80EC pcb fault help

    @ Matt1e The reason the fan has no neutral is because it is fed via permanent live and the neutral is switched to it on demand , so who knows nothing now . A Agile if your not going to help why bother being part of a forum to help people , keep your unhelpfull negative comments to yourself...
  8. T

    Protherm 80EC pcb fault help

    How have i overlooked electrical testing , when I have tested everywhere I have been told to test with the aid of protherms technical helpdesk , ie chcking for polarity and thermistor resistance readings and correct voltages everywhere specified etc etc , Some of you just want to get on their...
  9. T

    Protherm 80EC pcb fault help

    Thanks for that useless help , the main pcb was definatly burnt out as you could see where the transformer had exploded causing no display or anything else to work . I have only replaced the ignition board after extensive testing with protherm technical help even though I am drawn to having been...
  10. T

    Protherm 80EC pcb fault help

    I went to this boiler last and it was completly dead , nothing on the display , pump not running or fan , main pcb was burnt out ( the transformer ) new pcb ordered and fitted , now the display comes on and the pump runs but nothing else happens , fan doesnt run , +volts to the fan but no...
  11. T

    Drained down old system, re-filled it - now rads stone cold

    check for any bleed valves in the loft along the pipework , just cause the rads are full of water doesnt mean there isnt air trapped in one of the pipes.
  12. T

    Telephone line question...

    Unless of course he is using an old school dial up modem (very slow) but it is still internet!!!!
  13. T

    Valliant combi compact vuw gb236e

    As I thought it was the pump and not the divertor valve , new pump fitted and boiler is now working fine . Cheers guys
  14. T

    Back Bolier upgrade

    it isnt the immersion in the tank that tells the boiler to come on , it is a thermostat on the side of ythe cylinder plus heating controls , or you could use the immersion heater as well .
  15. T

    Replace Honeywell T6060 thermostat with Horstmann HRT3

    Blue should be neutral so that will go to 4 , red should be line so goes to 1 and yellow should be load so would go to 3 , red and yellow could be the other way around but even if they are it wont make any difference, only way to check is look what is connected to what at the other end of the...
  16. T

    Valliant combi compact vuw gb236e

    How old is that model and I hope their advice is good !
  17. T

    Valliant combi compact vuw gb236e

    Spoke to tech support this morning and they are fairly sure it is the divertor valve , cheers guys .
  18. T

    Valliant combi compact vuw gb236e

    Hot water is fine with no issues , today the central heating isnt working , what it is doing is coming on ,the temprature is rising very quickly , satisfying itself and switching off , neither heating pipe gets hot at all , Pump gets very hot and is very corroded on its casing , I am suspecting...