  1. S

    No Hot Water

    it'd check cylinder stat or MV (esp if 2 port) gas_man_gaz: why do you suggest header tank if gravity H/W? CH is also fed from this tank and it seems only HW is the fault?
  2. S

    New 3 port valve, olives question

    if the spindle was that stiff then the lever would not move over anyway..... replace the whole valve but makre sure your system water is ok...check your header tank.
  3. S

    Gas boiler KW question

    Thanks for helping me D_Hailsham, much appreciated. Is the heat input (gross/net) the amount of gas burned per hour then?
  4. S

    Gas boiler KW question

    Just a quickie - when a boiler says it has a heat input (or output) of say 18-21 KW ... what does this mean... is it the amount of gas it uses ????
  5. S

    Floplast external air admittance valve

    Thanks seco services - for some reason I believed they had to be above!! :shock:
  6. S

    Wireless room stat / receiver query

    i agree, a prog room stat is better if wiring is in place as you can alter it slightly - but my new house has no wiring for a room stat! I will check the boiler manual on fri and ask for help then (if you want to help me?)!! :cry: I am guessing :oops: that a combi boiler will have a L...
  7. S

    Floplast external air admittance valve

    seco servies - sorry if i am wrong (just always believed they were to be above spillover level so they would work properley - but this was for an aav on a stub stack inside the building and not externally).
  8. S

    Sludged up radiator

    John has given you some good advice, but on replacing the radiator, use some PTFE (about 3-4 turns) on the old olives and smear some jointing compound over the PTFE tape (if you have any) - this will help make a good watertight seal on re-fitting. Also be careful, sometimes sludge can be...
  9. S

    Wireless room stat / receiver query

    Was thinking there may be some advantages to it? .... ANyhow it'smore for my new house ... It has a combi WORECSTER make and has no room stat, just an older timeclock downstairs in the kitchen. The boiler is upstairs in the airing cupboard in the bathroom. I was thinking of adding a...
  10. S

    Unable to remove tap body to get to washer

    what's araldite mogget?!....
  11. S

    A rad in my living room!...

    Hi all - (again) :) - I have bought a new house and the only room in the house not to have a radiator is the (for some reason)!! living room (it has a leccy fire but still!!) .... anyhow, I would like to fit a new rad on the wall there (just a normal panel type rad really) - what size...
  12. S

    Unable to remove tap body to get to washer

    so the screw has come out of the top of the tap head, and the tap won't pull off?? - try loosening the limescale with a small flat headed screwdriver or squiet wd40 on it and let it soak in. f no joy, maybe new taps would be your best bet...
  13. S

    Wireless room stat / receiver query

    thanks for replying mrgas - my boiler is an old potterton flamingo II, o/v system - it currently has a switched L, N and E from it to the wiring centre. (which is the most common for older o/v system boilers i believe) If i were to replace my normal room stat for a wireless type, would...
  14. S

    Floplast external air admittance valve

    Just make sure the aav is installed on the stack HIGHER than the spillover level of the highest appliance (ie the basthroom basin) Didn't know external ones were now available! The older ones were only allowed to be installed indoors as the internal working parts would seize up outside...
  15. S

    Wireless room stat / receiver query

    Hi all Just a quick question: With a wireless room stat, (used mainly with combi's but even with a traditional o/v system) - how are they wired up (the receiver i mean)!! :) Do they need a permanent live similar to a prog room stat.... or can they be wired via a programmer...
  16. S

    Radiator bleed problem and washing machine smells

    Hi 1) does the radiator key fit the vent nipple? or is it covered/stiff with paint??? 2) washing machine smells - are quite common but does your machine have a trap? how is the waste piped up....
  17. S

    over flow problem

    as seco services says - if you turn the boiler stat on the boiler down to 0 (off) and the boiler stays on (as long as the programmer is on for h/w or htg) then this will prove that the boiler stat is faulty (STUCK SHUT) and thus the temperature getting up to about 100 degrees C and pumping over...
  18. S

    Ferroli Optima 700 wont light or spark

    have you got the boiler manual? if so.... give it to the engineer/plumber and he can then diagnose the fault properley anway
  19. S

    noisy boiler

    a blocked/sludged up pump will take longer to kick in to action and therefore will not shift the water quick enough at 1st and hence the noises