  1. G

    wooden door vent

    Not really.. my hall has higher floor than my bathroom so when bathroom door are closed there actually actually leave no space between the door and the hall floor so no space at all... pretty much sealed
  2. G

    wooden door vent

    Hi, I would need some advice on what vent to use and how to install it.. Basically, I need a vent in my bathroom door so my bathroom fan can draw air from outside the bathroom... Knowing that the door are 35mm wood doors, what vent can I use? What size should it be? I was wondering...
  3. G

    Low mains water pressure

    Hold on... have you tried to block (with a finger) your the mixer tap or some other basin tap? Can you try the following: - try blocking with your finger the mixer tap - can you block the flow? - remove the shower hose from the mixer tap and try blocking with your finger the shower hose...
  4. G

    Low mains water pressure

    1.5m is roughly 0.1bar and this is very very little. So the answer is - this is nothing to do with the height... there is something else wrong (i.e PRV or blocked inlet) Unless, basin Tap and shower are fed from different sources Maybe the mixer is broken?
  5. G

    permanent garden hose - how to connect?

    Hi, I thought this will be easier but apparently there are multiple ways of doing this so I need some advise... I've got 15mm pipe on outer wall of my building and would like to connect a garden hose to it permanently. I'm considering having a regular garden hose like this on...
  6. G

    Low mains water pressure

    to me, it looks like the cold inlet to the mixer simply needs to be cleaned How the heck hot water has higher pressure than cold water if not some rubbish in the cold water inlet... or, there are some PRVs and they are not in sync...
  7. G

    bathroom fan - how to delay start

    Thanks guys! Another question - do i need a vent hole in my bathroom door? I just installed new bathroom door which are pretty well aligned (no much of a space around the door for air in and out) which are on the opposite wall to the fan and window wall. If yes, how big should be the...
  8. G

    plaster disaster - installing bath screen

    got 100mm screws and plugs... and now it works fine :) possibly an overkill but it works!
  9. G

    bathroom fan - how to delay start

    This is something I never heard of! :) interesting... as it cost only around 10GBP... Thanks a lot ban-all-sheds!!! Might invest the 10quid to try it out :)
  10. G

    bathroom fan - how to delay start

    ericmac, yes the window is opening... lol, I like the option for 10days delay on the device :D
  11. G

    bathroom fan - how to delay start

    taylortwocities, i think I will go around theses lines.. all the stuff you mention and on 230VAC is done by this... http://uk.rs-online.com/web/p/time-delay-relays/3306654/ so sounds simple enough though a bit costly..
  12. G

    bathroom fan - how to delay start

    ericmark, regulations - i got window in my bathroom... PIR - same problem - when using loo fan will be on buttons, etc - you tend to forget about them.. and definitely you do not want to jump off your shower just to switch on the fan I guess I will simply get some time delay relay...
  13. G

    bathroom fan - how to delay start

    Hi, I've installed a fan in my bathroom that starts when bathroom lights are switched on and stops 5 minutes after the lights are switched off. Work great! Though, I do not need the fan to be on when I brush my teethes or wash my hands. But I need it only when the shower (combi boiler) is...
  14. G

    part rewiring

    ban-all-sheds, thanks for you answers. This is exactly what i was looking for. The problem I had is that I never came across similar setup before, thus - just asking. If this all sounds ok, then grant!
  15. G

    part rewiring

    Fan is on the same circuit for RCD. So, when testing my RCD all 3 things go off - fan, bathroom lights and kitchen boiler. Also, fan and kitchen boiler are fused together - so i have a single fuse in my switch box that switches off kitchen boiler and bathroom fan. On top of it I've got...
  16. G

    part rewiring

    Right, got time to look closer into this and what is then worrying me is that both the kitchen combi boiler and bathroom fan are on the same circuit. Moreover, boiler, bathroom fan and bathroom lights are protected by the same RCD. Is this actually possible that there are 2 separate...
  17. G

    2 estimates - huge price difference?

    Yes, all of them turned up in branded cars. The cheaper quote comes from a family business roofer, while the more expensive one is more of a regular company. Good English is slightly exaggerated as they are Scottish :) but they are local people I'm thinking of calling back the cheaper...
  18. G

    2 estimates - huge price difference?

    Right, what about the chimney flashing? The more expensive one includes two new chimney flashings (code 5 lead), but the cheaper quote includes only two lead back gutters. It makes me think that the lead back gutters are something else than flashings... so will lead back gutters do the job...
  19. G

    2 estimates - huge price difference?

    Hello, I hope someone can advise me in here... I got a leak in my roof that needs to be sorted out pretty urgently. The roof overall does not look in a healthy condition. It looks like the leaks is around the chimneys. So I got a few quotes. Most of them are around £3,500 but one of them just...
  20. G

    bathroom basin - not leveled

    Hi, It looks like I need some advice on this one... Got a new basin (on a pedestal) that I am about to install. Though, when put together against the wall the basin is not leveled... It is fine on sides (left-right), though the back of the basin is slightly lower than the front. So I...