  1. G

    fitting TRV's

    Well its actually highly unlikely that you can use the old ones, as the nuts will most likely not be compatable with the threads of the new valves (since they are 21yrs old) You'll most likely have to: 1. Drain down system 2: Remove old valves (careful of black sludge dripping on...
  2. G

    chrome waste pipe

    it should, but you can get chrome fittings you know, might look nicer
  3. G

    new combi boiler

    You managed to fit the boiler/pipework yourself, but dont know what pressure to fill it to? :shock: yes 1.5 is fine
  4. G

    Boiler pressure

    If you disconnect the filling loop and the pressure is STILL rising then it means that your heat exchanger has a small hole in it, so the cold mains is is entering the CH circuit through the domestic hot water heat exchanger. It probably just the filling loop passing though, so you will...
  5. G

    what van to buy

    thanks i'll try there :lol:
  6. G

    Recommendations for good stainless steel sink please?

    They just made a new one which sits flush with the worktop! pimp :lol: easy to fit too.
  7. G

    what van to buy

    Hey, i have about 8-12k to spend on a new van (well 6-12 months old) Just wondering if anyone can recomend a decent van, something around the same size as a vivaro or slightly smaller. Perhaps the volkswagon transporter or merc vito? Any reviews helpful
  8. G

    worcester 28 cdi hot water cutting out

    could it be that max and min burner pressures are wrong?
  9. G

    Help - shower is hot or cold but not nice

    Can you remember the make and model of shower, the cartridge probably needs replacing
  10. G

    Intermittent lockout on Baxi Barcelona boiler

    So your paying a monthly payment to BG to maintain your system then when something isn't right your going to call out a independent, not get BG to do it for free? strange :?
  11. G

    Help - shower is hot or cold but not nice

    Hows the hot water on other taps in the house? (are they a nice steady temp?) If so it's your shower mixer thats at fault not the boiler.
  12. G

    vokera

    good :lol:
  13. G

    Ideal classic lxff & fanned flue gas bolier problems, he

    DRain it down again, making sure you open all vents (including any near the cylinder) and make sure that the Zone valves are fixed open! Then re-fill it and see if it helps.
  14. G

    Holes for central heating pipes

    Speedfit is ridged but Hep20 is flexible
  15. G

    Faulty Mixer Tap

    Very easy to change on that sort of tap, and its almost defiantly the washer. Turn of the hot water (have you got a combi? if so just turn off the cold or isolate at boiler. Have you got a tank? Find gate valve and shut off) Then using a pair of grips unscrew the tap barrel (the brass bit)...
  16. G

    Brittony 80 Combi - Hot Water goes cold then hot then cold!

    Is water still coming out of the Blow out pipe? If so try isolate the cold water inlet to the boiler, you could have a hole in the DHW heat exchanger.
  17. G

    The phantom macerator

    Yes if the toilet was overflowing it would set the saniflo off. Fills up to a level makes a switch and BUZZZ :lol: Ball valve needs adjusting/replacing