Search results

  1. W

    Ricochet Monitor

    Using Ricochet Monitor, one of the pir's go red on walking past it , manual says "Device in alarm" but none of the others react like this. manual says "Only shown on MT2 Systems" On a walk test all are seen. So why is the Ricochet Monitor acting like this and only one PIR responding?
  2. W

    Texecom Head bang!

    Run that by me if you could? I have area A selected on all devices, do i need to set area A to Timed in Area timer options? Is using attribute 1 an alternative i.e zone set as guard, then tick Attributes 1 "access" is same as just "guard access found as a drop down in zone type" Have set as...
  3. W

    Texecom Head bang!

    Area Timers! found it. I assume Guard access is achieved with zone set as guard, then tick Attributes 1 "access"?
  4. W

    Texecom Head bang!

    Thanks have found a description of what i was after now, just trying to read and understand. I have entry exit1 and 2 front door back door, which of global timers is used for each (assume it is one of those) so i can set exit and entry time? Bell has defaulted as custom after learning, do i need...
  5. W

    Texecom Head bang!

    Having connected to coms port and successfully got wintex going, I am now trying to find in the manuals what all the options mean and what i need selected. However either I am reading the wrong manuals or for some odd reason none of them explain them. Is there a hidden manual somewhere? All i...
  6. W

    Ricochet Learn

    Ok I see now, reading up on it, you are basically receiving what is stored on controller, working on it local within wintex then sending the info you have worked with back to the controller. So receiving the data first as you say needs to be done otherwise you will not be working with the...
  7. W

    Ricochet Learn

    Click the receive and save to disk? Is that something to also do after any programming?
  8. W

    Ricochet Learn

    I Will wait for my coms lead then, hopefully make life easier
  9. W

    Ricochet Learn

    So having spent a few hours going through the manual, I am looking at how i can name the zones, so zone 10 will be say "lounge" etc but I can't see it mentioned anywhere. Is this the kind of thing hooking up my laptop to the comm port and using Wintex really is needed? (ordered the cable). I'm...
  10. W

    Ricochet Learn

    Thanks used keypad. Is it correct that the pirs (Texecom Premier Compact PW-W) do not flash. seem to recall last system I had flashed with movement
  11. W

    Ricochet Learn

    Can this only be done via keypad on Texecom 48 w or can this be also achieved via wintex?
  12. W

    Texecom premier elite 48 w

    Out of interest, I have Wintex software disc, what comms cable can i get to use laptop instead of using keypad. Might make life easier?? Something like...
  13. W

    Texecom premier elite 48 w

    No all wireless . Have not yet paired anything
  14. W

    Texecom premier elite 48 w

    Display shows System Alerts! then after entering code it goes through numerous tamper alerts from zone 1 to 8 then call alarm company. I have 5 pirs and 4 door contacts. I will want to get a front door entry/exit set and a back door entry exit set then have all pirs and door contacts armed / dis...
  15. W

    Texecom premier elite 48 w

    Thanks that worked managed to set date and time. Are those errors because system defaults are loaded? The manual looks pretty in depth, after pairing devices where should I ideally start re programming?
  16. W

    Texecom premier elite 48 w

    Just powered up the system for first time, did factory reset but when i enter default code to try and access any menu ideally to pair devices it just keeps scrolling automatically through various things not allowing me to do anything can someone give guidance?
  17. W

    Shelf

    like some decorative end piece, kitchen cornice or similar good idea as i have a length of cornice left over
  18. W

    Shelf

    Oh yeah! OK back to the drawing board lol Although shelf load will be negligible just a few decorative items (glass)
  19. W

    Shelf

    I was thinking maybe a bracket mid span on top. The bottom is not possible as shelf will be running along top of window opening. Might need to look at some planed 50mm timber. My Corbels are 300mm high x 200mm projection x 94mm wide. The Sagulator says 25mm MDF on that span and depth ACCEPTABLE
  20. W

    Shelf

    I am looking to make a shelf to span a 2.4m window supported each side on wooden Corbels. Shelf will be 20 cm wide. Would 25mm mdf be rigid enough or would i need something thicker.
Back