    Danfoss RET2001M no display when not in use

    this is the back of the programmer
  2. S

    Danfoss RET2001M no display when not in use

    I have the above room stat but it doesn't show anything on the digital screen until the programmer tells the boiler to turn on. Is this meant to have a live feed for display power all the time? It's a Drayton L711 1 channel programmer is it makes any difference
  3. S

    Block air bricks?

    It sounds as if the new path is too high and it may be above the DPC level which may lead to other problems with water getting above it. You should really think about lowering your path
  4. S

    Magnetic Filters

    Thinking about installing a magnetic filter to my heating system in the summer and wondering what's the most recommended for fitting on here? CD37i combi boiler. Seen the Fernox omega, Trappex centramag genesis & spirotrap mb3
  5. S

    How close to the boiler can you lag pipes?

    you mean the relief valve pipework?
  6. S

    How close to the boiler can you lag pipes?

    Cheers, it's been like this for 13 years, but I have lagged up to the clips below the valves, but i'll add on the extra lagging tomorrow. The condensate pipe is now also lagged, going to lag the condensate discharge hose as well. Boiler is in the garage.
  7. S

    How close to the boiler can you lag pipes?

    Just wondering if there's a set distance away from the boiler to stop the foam pipe lagging?
  8. S

    Rainfall Shower Position

    Starting to look at rainfall showers for when i do up the bathroom. Looking at the Mira miniluxe diverter erd. But wondering what wall would be better for fitting it to? Fitting it on the short wall at 700 or 800 wide or the ling wall at 1100 or 1200 wide? (still not 100% decided on the tray...
  9. S

    Worcester Greenstar 37CDi combi boiler sometimes gives cooler hot water

    hi John, Thanks for your reply, i'll need to get a thermometer to try this. Just for more info. It's only my wife & I in the house, this temp difference can happen when no one else is using a tap. Example, me doing the washing up and my wife sitting at the dining room table.
  10. S

    Worcester Greenstar 37CDi combi boiler sometimes gives cooler hot water

    bump (for anyone who was out at the weekend, like myself!)
  11. S

    Worcester Greenstar 37CDi combi boiler sometimes gives cooler hot water

    When using the hot water there's times when you turn the hot tap on and the hot water is noticeably cooler than normal. Then you can use the hot water tap again 5 minutes later and it's back to normal. Boiler is a Greenstar 37CDi
  12. S

    New boiler fitted but All radiators go cold after a couple of hours??

    what bit do you need to figure out on how to turn up the thermostat?
  13. S

    Wallpaper drying time behind radiators

    cheers, it's heavyweight vinyl (paste the wall stuff) I'll leave it another night and get the radiator working tomorrow
  14. S

    Wallpaper drying time behind radiators

    Just papered my hall, drained the radiator and rehung after papering, just wondering if there's a rough drying time before I get use of the radiator. didn't want to crank the heating on and the paper shrinks
  15. S

    Internal door won't close fully

    it may look like that from the outside, but what it's like on the other side, can you get a 2p coin all around it? or of you have a piece of the thin banding thats used on parcels, try to run that around the door when closed, if it's runs around ok, then it's the hinges and you may have to...
  16. S

    Drain blocking

    try to leave the last black connection on, but cut the bottom of it off so it can exit onto the main and hopefully keep the splashing at a minimum
  17. S

    Slow draining shower waste

    would an anti syphon basin trap help? would maybe help with the gurgling sounds coming from the basin/bath