Search results

  1. B

    Hydroponic System Syphoning problem

    do you have a link to that black one?
  2. B

    Hydroponic System Syphoning problem

    this will reduce the flow significantly.....1/2" as in 12/13mm
  3. B

    Hydroponic System Syphoning problem

    The anti syphon valve above is a 4mm one for use with car washers...looks like the kind of thing im looking for just a shame its not 1/2"
  4. B

    Hydroponic System Syphoning problem

    Thanks for your reply... the ballvalve isnt faulty and its not "evapotranspiration" its definitely a syphoning problem when the pumps turn off The balvalve is always going to be open as its acting as a mechanical safety device and the pumps turn on and off using a float switch just below...
  5. B

    Hydroponic System Syphoning problem

    I have just found this video on youtube of a similar system http://www.youtube.com/watch?v=d5822dpt7FA&feature=player_embedded#! At 25 seconds you will see an anti syphon valve any ideas if this is what im looking for?
  6. B

    Hydroponic System Syphoning problem

    Hi all, I am building a hydroponic system and have an ennoying syphoning issue.. As of the very rough sketch below. This part of the system pumps water from a main reservoir into a small 20 litre container and uses 2 x maxijet 1000 pumps of which have a non return valve on each, go into a...
  7. B

    Fixing down bilge pumps....

    Does the above sound like a plan?...any ideas on the sorts of bolts, nuts, washers etc I will need to go through the top of the tank and through the bilge pump handles?...I need to do it in a way where the pumps can be taken out without to much aggro should they need cleaning etc
  8. B

    Fixing down bilge pumps....

    good idea :) Trouble is it would need to be a solid fixed bracket the exact length of the gap between the roof of the tank and the handle of the pump in order to keep it fixed into place...this will also make it hard to get the pumps out for service Just had a further think about this...
  9. B

    Fixing down bilge pumps....

    Hello, I am looking to put a couple of these http://www.toolstation.com/shop/Power%20Tools/Pumps/SIP%20Submersible%202020%20Stainless%20Steel%20Water%20Pump%20/d40/sd3220/p33192 into 2 x 70 gallon coffin polytanks (one in each) the trouble is I need to somehow get them to stay...
  10. B

    Looking for rubber washers

    Sorted it.... 25mm open rubber grommits..the type electricians use..3.5p each + vat then push the male threads of the 25mm compression gland through the hole..tested it yesterday and staying bone dry :)
  11. B

    Looking for rubber washers

    the 25mm compression gland is perfect for a 1/2 internal diameter pipe, seals perfectly and cheaply (35p per gland) problem is getting the soft rubber washers to seal the gland nicely where it enters the bucket/s. I could use sealant like LSX but I am planning on selling these systems as kits so...
  12. B

    Looking for rubber washers

    hi... They are for a hydroponic system I am developing of which I need to seal 25mm compression glands onto the side of 20 litre buckets...I have 6 washers from a while back but am unable to trace them again
  13. B

    Looking for rubber washers

    Hi all, I spent Friday morning going round plumbers merchants trying to find 100 of the following rubber washer 40mm outer diameter, 25mm inner diameter and 3mm thick (has to be exact). I have found one place that sells a pack of 2 for £1.00 + VAT but this seems rather excessive. Ive...
  14. B

    equal recirculation between 2 tanks..

    thanks for the reply onetap..im going to do some experiments... A friend of mine since school has owned a local hydroponics shop for many years. Knowing I dabble in electronics and am an electrician by trade who plays with sms controlled alarm systems etc he asked me to design and build a...
  15. B

    equal recirculation between 2 tanks..

    The main 100L reservoir (25 gallon water tank) is considerably lower than the 2 x water butts of which are 330L...still having problems picturing this...can I be cheeky and ask someone do me a rough sketch please
  16. B

    equal recirculation between 2 tanks..

    Anyone any ideas on this? Sorry if I havent explained it to well....in summary I am trying to get the contents of one container to equaly flow between the other container Thanks
  17. B

    equal recirculation between 2 tanks..

    Hi all, I have a 100 litre loft tank of which is being controlled by SMS messaging (filling, emptying, mixing, various nutrient doses etc) which is for a hydroponics system. I want to be able to connect this to 2 x secondary tanks of which are 310 litre water butts...see an explanation...
  18. B

    Secondary tank working on gravity

    http://www.diy.com/diy/jsp/bq/nav.jsp?action=detail&fh_secondid=9219217&fh_location=//catalog01/en_GB/categories%3C{9372012}/categories%3C{9372021}/categories%3C{9372062}/specificationsProductType=tubs___bins/specificationsSpecificProductType=bins This makes things a lot easier and its got...
  19. B

    Secondary tank working on gravity

    I am thinking a small 3/4" bilge pump on the bottom of the water butt, connected to a timed relay of which will trigger with the main reservoirs solenoid valve and a ball valve at the top. My problem now is how to fix the ball valve and outlet fittings to the curved butt. I could now use a...
  20. B

    Secondary tank working on gravity

    Thanks...Looks like im going to have to re-think it so it either takes longer to fill or have another pump