Search results

  1. wakey77

    screed level and reusing it

    With the possibility of me sounding thick Can someone please explain to me an efficient and practical method of removing 25mm off a screed that has been layed for 2 weeks I'm my limited experience of screed after 3 days it's as hard as a monkey's head.
  2. wakey77

    screed level and reusing it

    With the possibility of me sounding thick Can someone please explain to me an efficient and practical method of removing 25mm off a screed that has been layed for 2 weeks I'm my limited experience of screed after 3 days it's as hard as a monkey's head.
  3. wakey77

    Cost of getting out of the ground.... 6x7m garage.

    I don't mate I price per m2 plus drainage and reinstatement etc
  4. wakey77

    Cost of getting out of the ground.... 6x7m garage.

    Price is dependant on a number of things and without seeing the job I can't really give you an accurate price but if for example everything is straight forward you'd be looking around the 5k mark that's what I'd charge in the west midlands
  5. wakey77

    Pressure washing new build houses

    Hi guys ive been been offered a load of work on a few sites pressure washing after the scaffold has been taken down to remove snots and and mortar stains left behind having never cleaned this type of work is there anyone on here who has and can you reccomend what kit i need and give me a few...
  6. wakey77

    How many sq meters in a day from two brickies on £120 each ?

    Tbh with wages on the up in the building trade at the moment id avoid anyone who,s prepared to work for £120 a day unless its a good old boy semi retired working for beer tokens and the love of the job that is lol
  7. wakey77

    Telling the difference between osb 2 and 3......

    Most fitters round here use osb myself included for replacement flat roofs but after reading through a few posts I'm not sure whether there are better products to use I have seen 12 & 18mm shuttering ply used too. Thanks in advance.
  8. wakey77

    Flat Roof EPDM and lead flashing - problem?

    ok so im no expert on epdm but have done 4 flat roofs using epdm succesfully so heres what i know. the epdm should be adhered to the brickwork using a contact adhesive and follow up the wall right upto the flashing. yours looks shoddy and cut short into the flashing however it may be possible...
  9. wakey77

    exmet to reinforce mortar joints in brickwork

    yes or no i know it seems to be popular on site but ive never been convinced due to the fact it stretches out when pulled.
  10. wakey77

    Blocks used in foundations

    Is it ok to use 3n 100mm concrete blocks in the foundation of a single storey extension I normally use 7n but have a surplus of 3n and therefore would like to use them up providing it will cause no problems. Thanks.
  11. wakey77

    Is this ok?

    just a thought is it advisable to bed an rsj on a thin 1 + 1 mortar joint to avoid this ? its not somthing ive ever done although i always bed catnics so cant see it harming anything.
  12. wakey77

    Poor rendering - what can I do to fmake it better?

    As said tyrolean it nice and thick
  13. wakey77

    Garage Conversion

    Thanks for the reply noseall I'd read it somewhere on some garage conversion site a while back and although I can see the flaws I wasn't sure whether or not it was an acceptable method.
  14. wakey77

    Planning permission - slightly over max height

    sorry just read another article it seems its different for outbuildings.
  15. wakey77

    Planning permission - slightly over max height

    http://www.planningportal.gov.uk/permission/commonprojects/extensions/miniguide check this link out it states you are allowed to go a maximum of 3m in height to eaves within 2m of a boundary. im in the process of building a single storey flat roof extension under p,d the corner of the...
  16. wakey77

    Planning permission - slightly over max height

    according to permitted development within 2 metres of a boundary your allowed to go 3m in height according to the planning portal?
  17. wakey77

    Garage Conversion

    not 100% on this but i think rather than dig a foundation through the garage door you can plug out a bearing either side and drop a catnic in to carry the new wall in place of the garage door. this may work out cheaper than digging and concreting a foundation and also save any damage /...
  18. wakey77

    Weep Vents

    There's vents you can get that have a hole the size of a biro head in them if your going to do anything swap them rather than seal them As for the mice get yourself a ferret they'll soon do 1 when they pick up its scent.
  19. wakey77

    Weep Vents

    Mate that's not a standard sized weep hole and unless my eyes deceive me that video was showing a wooden panel with mastic joints between them. If you want to spend your money and time on this good luck to you. Have you been watching Stuart little by any chance? :shock:
  20. wakey77

    Weep Vents

    im no pest controller but im pretty sure a mouse couldnt fit thru a weep hole most builders merchants stock weep holes of different types so yes you can plug out the joint or even better drill it out and fit replacements.
Back