Search results

  1. T

    SWA armour earthing

    Thanks guys...but i need some pics to understand better...can't help it, but i'm visualising george George Formby on a box playing a banjo, swinging a hoop on the hard shoulder of the M4 from what You've said! :? :) ...knew i shouldn't have had that joint! :shock:
  2. T

    SWA armour earthing

    Have discovered that the steel armour has not been earthed on the SWA that supplies the garage. The SWA is connected to 6mm T&E at a heavy-duty JB in the loft with the steel armour cut back before the cable enters the JB. Was thinking that I could clamp the steel armour and feed an earth wire...
  3. T

    doubling up

    thanks Q...I know it's best to double up but if the singles haven't been, is it against any accepted regs?
  4. T

    doubling up

    :oops: it's the bending over and doubling up the bare conductors I'm talking about.
  5. T

    doubling up

    Is it a requirement to double up on the conductors in appliances when fitting?...have noticed single and doubled in JBs and sockets.
  6. T

    loft runs

    Cheers Securespark.. Regarding the Insulation issue it is impossible to avoid contact with it, particularly as it is the norm now I believe to have 8" of insulation in the loft - the fact that only .5 of a metre is allowed before de-rating leaves nothing to work with really! Running the...
  7. T

    loft runs

    A few points that need clarifying regarding loft runs... Can cables be left running loose over joists and insulation? Do JBs have to be fixed to something? If cables are pinned to inside of loft joists and against insulation (4") - does the circuit require de-rating. If so, by how...
  8. T

    Dimmer for 2 -way lighting

    G9 are Halogen...Am I right in thinking that my load would be 240w (120 + 120)...so the rating required would have to be 500w?
  9. T

    Dimmer for 2 -way lighting

    I have a 2-way lighting circuit controlling to sets of G9 lights and would like to put a dimmer in circuit. - does it matter which switch is converted to a dimmer type or does it have to be the switch with the power feed to it i.e. the one with the 3-core and 2-core. The two sets of lights are...
  10. T

    Plaster cracking around lintel

    The mentioned problem keeps recurring. It is a box lintel on a cavity wall over door and window, the plaster cracks around it where it sits on the wall at both ends...cause is HGVs passing causing ripple like vibrations to run through house this is quite bad when they hit a bump or divot in...
  11. T

    Spur Clarification

    Is a FCU wired off a JB directly off the ring main considered a spur when considering the socket outlets - number of spurs rule, or does it just apply to spurs coming directly off the sockets themselves.
  12. T

    Spur Clarification

    TY JD. Is a single storey...easier to tap off ring using JB and run cable down to exact position of FCU - anything wrong with that?
  13. T

    Spur Clarification

    I have a ring main with 3 double sockets (not spurred off), 1 FCU directly connected to ring (i.e. not off a JB or off a socket), and 2 FCUs spured off JBs directly off the ring - can I spur off one of the sockets? Another point. Can I tap directly off a ring main using a JB to feed kitchen...
  14. T

    Grommets!

    :) Thanks JD. I owe you £50 - it's yours on provision of a reciept :wink: and a signed note confirming assistance in doing the bodge... sorry job :wink: :wink: :lol: It's a gift, If keep charging it'll stop working you know! :(
  15. T

    Grommets!

    Cheers guys. Well I'll be...... :o Fidgeted and fussed with the darn thing for ages, got mad, kicked toolbox and sat down for a cuppa and queried it on here. Not happy with the yes answers :( - guess what?...yes, went back to give it another go - goes in as sweet as you like first time! :D...
  16. T

    Grommets!

    Is it a requirement to use them...how do you stop them from popping out when trying to locate the back box in position?...particularly when there are 3 cables running through :x Does the cable's outer insulation have to run in to the box?
  17. T

    Socket - Light switch proximity

    Any reg regarding closeness of...?
  18. T

    Sink - Sockets proximity issues

    umm... is that from the tap or from edge of sink?
  19. T

    Sink - Sockets proximity issues

    Thanks. Hmm - some guy told me it was 1000mm.
  20. T

    Sink - Sockets proximity issues

    Are there any rules governing this?
Back
Top