  1. D

    louvre doors for ventilation

    Are louvre doors ecceptable to be used for ventilation for cooling perposes to a gas boiler room or should high and low ventilation be fitted? Meaning, should their be a certain distance between high and low ventilation? Many thanks
  2. D

    Paramount three ventilation requirements

    Can someone confirm what ventilation is required for a paramount three 115kw gas boiler. It says refer to BS6644 2005 for boilers above 70 kW net for further details. I do not have access to this document regulation and would appreciate some help. Thanks in advance
  3. D

    Turing off gas appliances when working on roofs

    Could someone tell me the correct procedure related to gas appliances when working on roofs. I seem to remember that if people are working on roofs and a gas fire is installed, the gas appliance must be isolated and a gas certificate issued to say the gas fire has been islated? Can anyone...
  4. D

    New installation of gas boiler

    Could someone confirm what action should be taken regarding the following incident? If a Gas Safe Registered installer fits a new heating system, commissions the gas boiler, issues a CP12 and registers the gas boiler with Gas Safe Register (Building Compliance Certificate) and at a later...
  5. D

    Commercial gas boiler registration

    When installing new domestic boilers, all should be registered with Gas Safe Register to obtain a gas safe compliance certificate. However, when installing commercial gas boilers I am told by Gas Safe register that this is not the case and this is done by a different governing body, but they...
  6. D

    Wiring help to install a Baxi Megaflow 28kw System boiler

    Hi all, Was wondering if some one could help me with the wiring installation of the above boil? I have replaced my old KESTON 25 Celsius (worst boiler on this planet), with a Baxi Megafloe 28 HE system boiler. The problem I have is the old boiler was designed around a comercial system, to...
  7. D

    Supplymentary Bonding

    If someone completed a minor electrical cert and he found no bonding to heating pipework would he need to carry out the repairs or simply note it on the Minor Elect cert. On a Minor Electrical Cert test would he have to test the supplementary bonding using a multimeter to ensure the reading...
  8. D

    wiring from low pressure switch to overheat stat.

    Feel a right prat :oops: Wrcester 28i junior I removed the wires from the low pressure switch and the overheat stat to test if the low pressure switch was blocked/faulty, and it was. Without thinking or checking I assmed the diagram would be in the manufacturers instructions but cant...
  9. D

    commercial district heating

    Thanks Lee, is there a certain thickness of lagging they should be using for the 35 mm pipe?
  10. D

    commercial district heating

    Thanks mate, its a repipe to replace some rusty pipe that a guy is doing for me, I just wanted some info to get a rough idea of what the finished pipe-work should look like. I dont want all the hassle of trying to get them back if its not fitted right.
  11. D

    commercial district heating

    I wonder if anyone can recommend a good book that discribes the correct method of installing commercial district heating pipework in properties. Steel pipeworking is being fitted in loft areas and down the side of a gable end wall and being run in 35mm steel pipe. Dose anyone know how far...
  12. D

    coal fire and gas flue regulations

    I was was wondering what are the regulations regarding a old bedroom coal fire flue and a living room gas fire flue. If the gas fire flue runs up the side of the bedroom coal fire flue, should the bedroom coal fire be bricked up due to the possibity that fumes from the gas fire cold enter the...
  13. D

    Commercial boiler flues and the clean air act

    Many thanks again Lee, I dont have the Ige/up/10 doc but will try and find it on the net.
  14. D

    Commercial boiler flues and the clean air act

    Thanks Lee for your reply, Its not as striaght forward as it seems, Started off with 3 already installed a couple of years ago but the supply demand has grown so decided to add 2 more to keep the price down. Do you have website I could visit to print off the information you have provided or...
  15. D

    Commercial boiler flues and the clean air act

    Good morning all. I wonder if someone could help me and explain what is meant by the clean air act when installing boiler flues. I have a plant room and am looking to install 5 x Potterton 115kw boilers with vertical flues 600mm apart; the top of the terminals to the floor is approx. 5m...
  16. D

    gas manuals

    so why did you not offer to give them to me rather than being sarcastic
  17. D

    gas manuals

    Do i detect a not of sarcasm on this thread? Anyway just purchased the 2 manuals needed.
  18. D

    gas manuals

    Thanks for your uselesss reply, if you cant provide advice do one mate
  19. D

    gas manuals

    I was looking to find a gas manual for my gas fire and boiler and dont really mind paying a few quid to get them as it saves me trawling through the web to find them. I was wondering if anyone has used If so what is there service like :?: (Posted on another thread in error)
  20. D

    Keston Celsious 25

    Can sone wise owl help me with a little problem with my boiler. When the boiler fires up it goes through the full firing up sequence fan, pump then when it ignites, the boiler back fires, with a large bang, just like a car backfiring then a flame comes out of the air intake at the top of the...