Search results

  1. P

    Dye recall

    http://www.sky.com/skynews/article/0,,30000-1171557,00.html
  2. P

    washing machine with hot and cold feed

    Are we talking "Dishwashers" Or "Washing Machines" :roll:
  3. P

    Hotpoint WM52

    Our Hotpoint WM52 washing machine developed a fault which was similar to worn motor brushes, Upon further investigation it was discovered that the brushes still had plenty of meat (Only half worn), But the drum would not rotate when I tried to turn it by hand, It has been working perfectly until...
  4. P

    Monitoring house light status

    Why do you want to do this :roll:
  5. P

    Cable conduit

    I always thought it was to protect the pvc cable from the acidic effects of the plaster :roll: And it will stop "Drawing pins"
  6. P

    Earthquake

    Anyone Feel The Earthquake In The North Of Wales At 6.45pm Tonight :shock: :shock: :shock:
  7. P

    Cable Size Calcs..... too much !!!

    Another point is, Any steel girder which has cables running through it, Or very close to it, Should be bonded to the main earth terminal using a minimum 10mm2 earth cable,
  8. P

    Adding and removing! panel heaters

    Plug & FCU fuses Come in 1, 3, 5, 7, 10, & 13 amp ranges, But only the 3, 5, & 13 amp fuses are commonly available, I think "RS" still supply the 1, 7, & 10 amp,
  9. P

    10.5kw Shower on 30a Jointbox

    I have five teenage kids, And believe me, My shower sometimes runs for 2Hrs or more when they heard themselves through the shower one at a time, Also like I said, The jointbox terminals don't carry the actual current, They just provide security & seperation of conductors,
  10. P

    10.5kw Shower on 30a Jointbox

    Went to relocate an existing 10.5Kw shower last week, And discovered that the 10mm2 T&E cable had been jointed with a 30a joint box under the floorboards, This shower takes about 45a, So was well over the top for the jointbox, The shower was supplied from a 50a MCB/30ma RCD, The jointbox had...
  11. P

    Cable Size Calcs..... too much !!!

    I take it that you drilled through an "RSJ" (Rolled Steel Joist)? ie: a Steel girder, Or was it an ordinary wooden floor joist?
  12. P

    Cable Size Calcs..... too much !!!

    Oh No.....You drilled through an RSJ, That's Naughty, :twisted: :shock: :evil:
  13. P

    Electric Supply for Built In Oven

    The "Electrolux EOC6630" Is a 3kw oven, So You Have Two Options:- 1) Install a New 30a Ring Circuit In The Kitchen, So You Can Plug The Oven Into a Socket, And Have Capacity Left For Other Appliances, (ie Kettle, Fridge, Toaster Etc) 2) Install a New Dedicated 15a/20a Radial Circuit For...
  14. P

    Reformatting

    Does a Full Reformat of a Computer Clear The Registry?
  15. P

    Part P & Exterior Christmas Lights

    Lawnmowers? Who mentioned lawnmowers, And what have they got to do with exterior decorative lighting :?
  16. P

    Part P & Exterior Christmas Lights

    Isn't it nice to see everyone decorating the exterior of their houses with christmas lights every december, :D Ranging from simple lighting around the front door or windows, To whole house & garden installations, Looking like santa's grotto 8) Most of this "exterior" lighting is operating...
  17. P

    Cable type & regs

    The Earth In 6mm2 T&E Is Solid, The Earth In 10mm2 T&E Is Stranded, :?
  18. P

    Paul_C ?

    Don't argue with an idiot; people watching may not be able to tell the difference.
  19. P

    Paul_C ?

    Ok Cheers :?
  20. P

    Paul_C ?

    Are You By Any Chance The "Paul_C" That I Used To Know From Birkdale, Southport, Merseyside :?: