  1. J

    Testing

    Hi guys Did a IR test on my CU. On my N/E all results were good (>1000) except for kitchen (42.9) lights (44.7) boiler (45.3) shower ( 44.6). I know they all pass but as a lower reading would this indicate age deterioration? Property is nearly 20 years old. Your thoughts please
  2. J

    ADS

    Thanks Col.Jack that's the part I forgot.
  3. J

    ADS

    Dear dingbat I am still learning hence why I am still asking. Not once did I say I was competent. Some things I am still unsure about which is why I would rather find out now before declaring I'm competent.
  4. J

    ADS

    Which is?....for example a system not protected RCD with rewireabke fuses. What would the protection against electric shock be. ?
  5. J

    ADS

    Which is?....for example a system not protected RCD with rewireabke fuses. What would the protection against electric shock be. ?
  6. J

    ADS

    When completing certificates if the protective measure against electric shock is not ADS, what should be stated?
  7. J

    ADS

    When completing certificates if the protective measure against electric shock is not ADS, what should be stated?
  8. J

    Questions

    Sorry to be vague, I remember using it at collage when the tutor wass showing a calculation but I cant' remember what it was for. Yes Spark I think it was with regards to Max. ELI.
  9. J

    Questions

    'rule of thumb' calculation. Is the value 1.6?and where would we use it?
  10. J

    Metre Tails

    Ah seen it now :)
  11. J

    Metre Tails

    Thanks for the help and the sarcasm. Though I don't understand what I've spelt wrong ;)
  12. J

    Metre Tails

    no it would be a metre at the most, and it wouldn't be more than three. So who would do it? There's no isolator switch but are the tails between the CU and the metre mine or DNO?
  13. J

    Metre Tails

    With regards to metre tails, who has the authority to extend them? I understand you can't extend them 3 metre's from the incoming supply but can't remember who can extend them. Thanks :)
  14. J

    Recommendations

    Hi guys, can anyone recommended a cordless hand tool to use as an Electrician? Im looking for one with drill, hammer and chisel . Thanks :)
  15. J

    More calculations

    0.5mm. Thanks for that. Couldn't work out which way round. Regs say operating current of protective device cnt be 1.45 x greater than current carrying of cable. Yet I cnt achieve this,so what do I do?
  16. J

    More calculations

    This is a fictional example. A kitchen ring has a design current of 26a Protection of bs60898 32a Cable will run through 0.5mm of insulation and be installed as ref. 102 in stud wall with cable touching wall. Therefore current carrying capacity= 32x0.88=28a Go to selection of cable...
  17. J

    Design ideas for loft conversion

    Over 10 years ago. Anyone know of any lights designed to sit in awkward angles?
  18. J

    Design ideas for loft conversion

    Not sure exactly but put it like this my dad looked at some fancy pendant lights with a 5 inch drop n that was too low for two blokes at 5ft 8
  19. J

    Design ideas for loft conversion

    Not sure exactly but put it like this my dad looked at some fancy pendant lights with a 5 inch drop n that was too low for two blokes at 5ft 8
  20. J

    Design ideas for loft conversion

    Hi guys So, my Dad has got a full loft conversion which acts as a bedroom. The current three point spot lights that are up sit on a beam that goes across the apex and doesn't look great. I was going to build a flat false ceiling running parallel with the appex and install some...