Search results

  1. M

    no circulation help

    Cheers boys i went today armed with a new pump,anti gravity valve and i bought some drain springs from wickes so i got there at 10am and i didnt mess about i draines it down had to cut the pipework above the anti grav valve as it was impossible to undo it hadnt moved for 30 years so i used...
  2. M

    no circulation help

    Hello im just wondering if you can help im a bit stuck ive been out to a power flush and i had warned that it may not work so i went done the flush and still the same proplem which is "the system is a conventianl boiler, back boiler the customer rang me on sunday he fitted a new pump but the...
  3. M

    Open system not re-filling

    Right it's obvious the lad just wants to know if he can refill the system without getting someone in who will tell him it needs a powerflush and charge him a few ton. Have you got in the loft and disconected the cold feed at the tank and then hooked a hose to it from a mains water pipe so you...
  4. M

    Worcester 24i strange fault

    It has fan running then starts sparking and it seems to be running as it should be i mean it certainly isnt sluggish and if the fan was faulty it wouldnt open the aps to allow sparking and it doesnt start sparking until the fan has started
  5. M

    Worcester 24i strange fault

    Gas guru good answer i was there for a good 45 min before i thought hang on is the cap on,but it was.I am doing this as a favour for a old lady i know and i am really trying to keep the cost to a minimum so to tell you the truth im taking a 24i out tomorrow and i was going to take it with me and...
  6. M

    Worcester 24i strange fault

    Thanks lads,am i right in saying you cant link them aps out just to test? and i was thinking fan but it does seem to be running ok,i know you can never be 100% but it is a vertical flue and maybe a blockage as you say?
  7. M

    Old pipework failed, whos fault ?

    Thanks lads,I am gutted because this all came from me trying to do 2 things (1) save a bit of time (2) save disturbing their bathroom tiles and keeping the pipework looking neat to the combi. I should have done what I intended to do but we all make decisions like this and thank god we...
  8. M

    Worcester 24i strange fault

    I need some advice on a worcester 24 i fault please lads. It is standard 24i now what happens is for c/h and h/water it goes through its sequence it starts to spark and then it dosent ignite,now i was thinking gas valve but if i blow down the aps tube it starts to spark then fires up every time...
  9. M

    Old pipework failed, whos fault ?

    You think i should im waiting for a call back so i am telling myself that i will say "listen i was trying to help after the accident but got told i wasnt needed so its too late now im not intrested in helping now,goodbye"
  10. M

    Old pipework failed, whos fault ?

    I have just had a call from their son's telling me to pay them the money back for the job and they want £2.650 for the cost of the new ceilings and for the pipework to be fixed. I told him I will never pay the money back and as far as the ceilings go i wasnt to blame but if id been treated...
  11. M

    Blocked Cold Feed?

    I would go no further than what the lads have said and cut the 15mm above the tee and make sure you have something to poke down i bet you will find it solid with sludge and end up having to force it clear,when its clear get yourself some strong cleaner and leave it in for a week or two then...
  12. M

    Could i attempt to convert gravity fed to fully pumped...?

    If your just changing over to fully pumped then if your quite competent you will be ok as it isnt difficult if you know what your doing just be careful and if your lucky then a couple of tees,blanks and 2 port mzv and you might be done ,it all depends how its been piped before just make sure its ok
  13. M

    Old pipework failed, whos fault ?

    Thanks lads for your advice. I agree that i have been naive as i did know it might not hold but surely were all nervous when changing a old system over to a sealed system. I got a letter today telling me they want me to give them £3.500 by the end of 14 days or it will get to court.I charged...
  14. M

    Old pipework failed, whos fault ?

    Im in my first yr as my own boss and for just over a year i had no proplems tht werent easy to sort out. I done a boiler change old floor standing to combi system i also fitted towel rail rad,new trv's and powerflushed it. I had to use the old circs as hot and cold supplys to combi,they...
  15. M

    Worcester greenstar 28i junior - No Hot water

    Is the air vent open inside the boiler,they are very odd sometimes the juniors if thereis any air in the boiler it wont operate,also make sure presssure s right up and then look at d/valve or flow switch
  16. M

    Alpha 240 boiler

    No of course i dont,but alpha;s(come on)and what i should have said was get rid get a flush and your ok,because alphas arent great and not cheap for spares
  17. M

    Alpha 240 boiler

    I would get rid if you can. It sounds like it needs flushing or get a new h/ex but your not solving the true proplem of sludge and t will affect the new h/ex in the future so get rid unless it turns out to be a faulty stat or the diapraghm on the diverter is gone
  18. M

    So.... how can I connect this...

    Extend waste pipe and get 2 90* elbows,get a 1 1/2 slvent strap on boss and connect on elbow,you can get them were they dont need screwing just glued and then your done
Back
Top