  1. I

    IP44 or IP65 for bathroom?

    Title says it all, looking to buy some downlights for bathroom IP44 - http://www.screwfix.com/app/sfd/cat/pro.jsp?cId=101162&ts=57670&id=93450 IP65 - http://www.screwfix.com/app/sfd/cat/pro.jsp?cId=101162&ts=57670&id=48434 The IP65 looks like the light is recessed quite far back in the...
  2. I

    Quick lesson on installing UPVC windows

    Hi all, My windows have turned up for my house, ive got to get 3 installed before the scaffolding goes on Monday. The problem is my fitters cant make it untill the end of next week. So ive decided to fit these over the weekend, theres 3 to fit all 1200mm x 1000mm, 2 in a cavity brick wall and...
  3. I

    Dot and dab and electric cables

    Hi all, On a block wall that is about to be dot and dabbed. There is cables on the block running to where a socket etc will go. whats the proceedure? Do i fit the back boxes first then D&D or do i D&D and then cut out for the boxes? Thanks
  4. I

    Anyone used a vent like this?

    Just got this from the planning portal - http://www.planningportal.gov.uk/england/genpub/en/1115314018395.html Soil and Vent Pipe This pipe is used to vent the smells and gases that form within the sewer system and help to transfer the waste vertically to the nearest inspection...
  5. I

    Claiming VAT back?

    Hello, Im currently rebuilding my house (loft extension that required the roof removing and rebuilding at a steeper pitch). Ive basically been the project manager and have bought all the stuff my builder has required. Ive heard that maybe i could claim the dreaded VAT back? Anyone know if i...
  6. I

    Wall border tile problem

    Hi all, My misses wants to use a border pattern when i tile the bathroom, the problem is shes picked a border that is meant for floor tiles! So they stand about 2mm proud of the wall tiles, can i stick the tiles on with a extra thick layer of adeshive to bring the tiles out to the same level...
  7. I

    Insulate Loft Hatch

    Could you install one of these? http://www.screwfix.com/app/sfd/sea/searchresults.jsp;jsessionid=2HM0B5DKBASSGCSTHZOCFFA?_dyncharset=UTF-8&howMany=15&searchText=loft+hatch
  8. I

    2 rads off one "tail"

    Hi all, I remeber this being posted a while back but cant find the thread and was wondering what the outcome was? I have a main run of 22mm pipe with 10mm tails to the rads. I was wondering could i run 2 rads off one 10mm tail? The tail is the first in the run off the 22mm and the second...
  9. I

    Anyone used a vent like this?

    Hi all, Ive posted this in the plumbing forum but have had no luck - Anyone used one of these vents to vent a soil pipe? If so what do you think? Will it work well with a marley modern? Cheers http://www.screwfix.com/app/sfd/cat/pro.jsp?id=79071&ts=15051
  10. I

    Anyone used one of these vents?

    Anyone used one of these vents? If so what do you think? Will it work well with a marley modern? Cheers http://www.screwfix.com/app/sfd/cat/pro.jsp?id=79071&ts=15051
  11. I

    Window sills before or after plastering

    Thanks again noseall, yes its the window boards, think i'll dot and dab first then, it should be easier, then attach the boards and get the plasterer to skim them in. Cheers! P.S. Noseall i could do with you being my personal advisor on my build as your a bag of knowledge!!!
  12. I

    soil pipe vent regs?

    Thanks noseall, Is that 600mm above or 600mm away? and is that measure ment from the opening in the window?
  13. I

    soil pipe vent regs?

    Hello all, Whats the regs for distance from and or above windows for a soil pipe vent? Cheers
  14. I

    Window sills before or after plastering

    Hi all, question as above cheers
  15. I

    Moving water main

    Thanks for the replies so far, the pipe is a black plastic one. i've got some of that blue pipe and some push fit fittings. The pipe does feed 2 properties so im going to do as much as i can and leave the final joining to last so minimising the time it will need to be turned off!
  16. I

    Moving water main

    Hi all, my kitchen has been moved to another room, i want to move the water main from the old kitchen to my new "utility room" which will involve digging up my drive etc. Is there anything i should be looking into before doing this? Im ready for a bit of graft with a spade! Thanks
  17. I

    And another question

    Thanks spark, I'll go for the 2.5mm ring then, that should keep us all happy! BTW yes building control are informed. Cheers
  18. I

    And another question

    I have an upstairs ring, and a downstairs ring. I am also planning on having a kitchen ring powering - oven, fridge, washer, cooker hood and dish washer. It will be difficult to run a return the the CU. Can i be lazy and wire this circuit as a radial (wired in 2.5mm with a 20A MCB i think?)...
  19. I

    Struggling to not use a junction box

    Hi all, Dreaded downlights. Im struggling to not use junction boxes in the ceiling void. The only solution i can find is to have a "loose" junction box in the space and pull it out through a down light hole. The other solution would be to permenatly join the cables - maybe crimping them, but...
  20. I

    can i loop and out of these?

    The most lights in one room will be 6 with around 1 meter of cable inbetween lights, the lighting circuit is currently in 1.5mm will it be safe to drop to 1mm for the lighting "daisy chain"?