    Honeywell G2 External Contacts

    Hi If i want to add protection to my gate and add it to my intruder alarm system whats the best way to do this? I do not think Honeywell make an external weather proof connector for the G2 range? Can i use normal door contacts or photocells? I bought a wireless door contact with external input...
  2. I

    G2 Exit Time & Door Contact

    I can confirm that the door contact is fully working as if i set it to a 15 second exit time, then close the door, after the 15 seconds I get the double bleep and 'system is full set' if the contact was faulty it would say zone open (did before when i had a contact fail). However, just to...
  3. I

    G2 Exit Time & Door Contact

    I've had a Galaxy G2 Panel in place for several years and always had it set to be a 15 second countdown timer before the system full sets. I have a door contact set as FINAL. However, is it possible whereby when i'm exiting the house and full set, that the system can interrupt that the countdown...
  4. I

    Honeywell P026 RIO

    Despite being a new panel it was the fuse in F4. I swapped it with the one in F3 and power was applied. Fuse confirmed dead by multimeter.
  5. I

    Honeywell P026 RIO

    I'll check them, even though its a New panel!
  6. I

    Honeywell P026 RIO

    I've purchased a P026 rio and for some reason when i connect a keypad to the 12V+1 and 0v connection the keypad works but when it's connected to the 12V+2 second set of power connections it doesn't get any power. Am i missing something or is the panel faulty?
  7. I

    RIO or Power RIO

    Yep when i added the RF portal I moved the 680ohm(i think) from the keypad AB to the RF portal AB.
  8. I

    RIO or Power RIO

    I Currently have a G2 panel and on the AB lines I have a cable from the panel AB to keypad AB, then from Keypad AB to RF portal AB. For the powered RIO can the main G2 panel have a 2nd communication line going from the main board to the Powered RIO? How many data lines daisy chained can be used...
  9. I

    RIO or Power RIO

    When would use choose the Honeywell POWER rio over just the normal RIO? I'm assuming the powered rio would allow you to run an additional bell box easier (by programming the outputs?), but are there any other benefits? Thanks
  10. I

    Wireless smoke alarm testing

    On my intruder alarm system I have some smoke detectors set up as a fire zone which assume means they are monitored 24 7 and will alert me if activated. However if I were to test them using a paperclip will it just test the smoke detector sounder or will it also signal back to the panel and...
  11. I

    Hikvision Alarm Input Door Contacts

    Cheers, thanks for that.
  12. I

    Hikvision Alarm Input Door Contacts

    could you send me the link you found please? thanks.
  13. I

    Hikvision Alarm Input Door Contacts

    http://www.ebay.co.uk/itm/CQR-SC570-White-Door-Contact-With-Selectable-EOL-Resistors-G2-/381035347503 These are what I use for my intruder panel.
  14. I

    Hikvision Alarm Input Door Contacts

    I'll give that a go, just wanted to use the same door contact for aesthetics so they looked the same, but if i need to use one without a tamper, then so it be.
  15. I

    Hikvision Alarm Input Door Contacts

    I've tried to hook up an alarm door contact to my NVR to switch to full screen on a particular channel in the event of a door being open. It kind of half works.... I've got everything set up, but can only get it to switch to full screen using the door contact tamper switch. Whether i set the...
  16. I

    Honeywell Galaxy Groups

    I'm looking for some clarification regarding the groups feature of the honeywell galaxy g2 range. Is it right that it means if ihad a keypad in both the main house, and one in an outbuilding, by using groups, i can unset the main house leaving the outbuilding set, then I can go into the...
  17. I

    Honeywell Original vs ADT Panel

    Yeah i know thats possible, but panel/program wise if it the same panel? Just wondered why they would have separate branded ADT panels, and whats so special about them.
  18. I

    Honeywell Original vs ADT Panel

    Yes it has ADT software as out of engineer mode it comes up as ADT and the included manuals have ADT stuff on.
  19. I

    Honeywell Original vs ADT Panel

    I've currently got a honeywell g2-12 panel and got my hands on a g2-44 panel to expand my zone capability, but within the docs and the banner on the screen its an ADT version. - yes it was an ebay job as a left over from an install and didnt mention it was and ADT version. Can anyone advise...
  20. I

    Hikvision NVR Alarm Input/Output

    just a door contact so when a door is opened the camera pointing at the door goes full screen, however i'm assuming for the full screen view option it will only apply to a locally connected monitor to the NVR and not over the web interface, which really defeats the object when the NVR is located...