Search results

  1. E

    PIR sensor opinions

    basically its about being able to hide any wiring. the wall the sensor and light will(might) be fitted to backs onto my garage, so any wiring will only be seen in the garage, as I will drill holes behind the fittings through to the garage. getting a cable to the door means visible...
  2. E

    PIR sensor opinions

    Great advice guys, I forgot to mention that the porch is closed in and the reason for waist height is literally to detect entry to the porch and switch a light to illuminate the porch itself to aid opening the front door at night etc etc, its not intended to detect anyone approaching as the...
  3. E

    PIR sensor opinions

    looking to fit a sensor light into our porch, but there are no sensor light (combined) untis that are to our taste. So I have thought about fitting one of these, at just about waist height (to prevent any unwanted triggers by passers by)...
  4. E

    Hot Water pipes "ringing"

    yes its only the kitchen tap, so I guess that rules out the float valve in the header tank (should have spotted that :oops: ) The kitchen tap is a basic cheapo mixer tap which really needs repacing as it leaks when turned.....I have replaced the o rings on it.....
  5. E

    Hot Water pipes "ringing"

    When we start to run the hot water tap in our kitchen the hot water pipes start to "ring" and reverberate through the system , in a similar way the toilet water feed pipe sounded when the float valve needed replacing/fixing......the only thing I can think off in my limited knowledge is that its...
  6. E

    Dyson DC04 question

    checked all of the ducts, motor filter isnt washable is it so thats as it is, all hoses clear......just washed the blue filter and the lint one, see how the goes when they are dry......Thanks for the advice chaps ;-)
  7. E

    Dyson DC04 question

    No I havent it doesnt look to caked in crap to be honest, but ill give it a try whats the best way to wash it ?
  8. E

    Dyson DC04 question

    Our Dyson DC04 is not as powerfull as i think it should be, filters are not too old and all the removable pipe bits are clear, and i have removed the beater tube and de-haired it so its clean.......however think the dust and crap that it picks up should be flying round inside the clear tank at...
  9. E

    Meter change..

    I think its the same in the MANWEB area SP will change Iron Clad cutouts FOC. They want them off the system, and while they are there they will change your tails. If in any doubt report a smell of burning coming from your meter cupboard to the DNO. they "should" respond smartly to that...
  10. E

    Bycycle brakes

    I think its me thats barkin mate, :roll: I must be missing something
  11. E

    Bycycle brakes

    After months of nagging I have finally persuaded the boy to put brakes on his beloved BMX bike, however we are struggling to set up the spring tension on the caliper as below. does anyone have any idea of the procedure to tighten up and set the tension so that the caliper springs away from the...
  12. E

    Replacemant oven

    we (She) hasnt picked out an oven yet, but the installation instructions will be followed as far as "Reasonably Practible" to quote my DNO Operations Green Book :wink:
  13. E

    Replacemant oven

    Our current oven is connected via a 13A plugtop plugged into socket that is fed from a fused switched spur. ie the socket has a 2.5mm T&E feed from the spur and the spur is fed via a 2.5mm T&E connected to an old 4mm cooker feed elsewhere in the kitchen. NOW most new ovens I can see demand a...
  14. E

    C/H sealed system pressure question

    its been like this for a while, will any damage have occured.......system works fine at the moment.....
  15. E

    C/H sealed system pressure question

    Central heating system is a Y plan I think (3 way motor valve)....with a worcester 24i boiler (not combi). When cold the pressure guage is at zero, but when operating the pressure is in the green range on the dial......but falls back when totally cold again, I have topped up the system a couple...
  16. E

    Bellbox replacement

    With my installation being nearly 14 years old, the external bell box has a weathered appearance and no doubt the battery is totally dead, so im looking to replace it with a more modern one that has the brighter flashing leds etc etc. my system is an optima accenta 6 zone panel....Can you...
  17. E

    Some pics from the Network

    Into the Workshop.....heres a 500Kva 11000/6600/415V transformer without its cbale connection boxes fitted , obviousley the smaller connections are the HV ones and the voltage links are at the bottom, which alter the windings on the HV to either 11 or 6.6KV Heres another Vacum circuit...
  18. E

    Some pics from the Network

    A 33KV Circuit breaker in an open S/S compound....... And its modern equivalent (actually this one is 20 years old now) but its an SF6 vac 33Kv breaker. We have a cutaway version in our training school which shows the inner workings and the GAP between the two contacts it switches is 5mm...
  19. E

    Some pics from the Network

    Seen that done Spark123....or we have a portable trip battery with LONG leads for "suspect" breakers. But wherever possible the switches with an operating restriction on them are made "not live" before operation.........Thats not to say the modern stuff doesnt have its faults....both types of...
  20. E

    Some pics from the Network

    Seen that done Spark123....or we have a portable trip battery with LONG leads for "suspect" breakers. But wherever possible the switches with an operating restriction on them are made "not live" before operation.........Thats not to say the modern stuff doesnt have its faults....both types of...