Search results

  1. S

    Ideal Icos HE15 problem

    I have an Ideal Icos HE15 standard boiler. Hot water cylinder in the airing cupboard. So the boiler just comes on when the timer and thermostat of either the room thermostat or water cylinder thermostat require heat. However, today, neither of the heating or water were on at the programmer...
  2. S

    ideal classic he12 vs ideal icos he12 boiler

    are there any specific things that go wrong with the Ideal ICOS HE or is it just a blanket statement that they are rubbish?
  3. S

    ideal classic he12 vs ideal icos he12 boiler

    out of interest..... in what way is the ICOS model unreliable ? My potential installer says that the old M series ICOS were not that good but that the newer HE model is fine. Thanks.
  4. S

    ideal classic he12 vs ideal icos he12 boiler

    If I change to a combi........ Is the ideal isar he 24 ok as a combi boiler to go in a kitchen cupboard? any positives or negatives on this one? Thanks.
  5. S

    ideal classic he12 vs ideal icos he12 boiler

    ok thanks, i will go for the ideal classic then.
  6. S

    ideal classic he12 vs ideal icos he12 boiler

    so is the ideal classic an ok boiler then?
  7. S

    ideal classic he12 vs ideal icos he12 boiler

    Hi Possibly going to replace my system boiler (not combi). Shortlisted to 2:- ideal classic he12 vs ideal icos he12 boiler. Have chosen these as they fit into a standard kitchen wall cupboard which i need. the classic seems about £100 cheaper (inc vat). Anybody got any...
  8. S

    boiler pump over run problem - advice needed

    Hi, I have a ferroli sigma 40-60 boiler in the kitchen. This has a pump over run circuit to the pump in the airing cupboard. The problem is that when the timer and the room thermostat call for heat this starts up the boiler BUT there is a fault on the boiler PCB in that it does not send the live...
  9. S

    noisy boiler

    Sorry to sound stupid, but how/where do i put it into a radiator? Many thanks.
  10. S

    noisy boiler

    Hi Thanks for the advice. This product costs about £20, what would a reasonable figure for power flushing cost and what exactly is power flushing? Just for info, I have 1 downstairs radiator and 4 x upstairs radiators + the hot water cylinder in the airing cupboard. (not a combi). Thanks.
  11. S

    noisy boiler

    Hi, I have a Ferroli sigma 40-60 boiler. only 2 years old. but seems to be kettling a lot (loud rumbling in the boiler/pipes ?) - is that kettling? Would using Fernox Boiler Noise Silencer Concentrate 500ml help. Mine is an open vent system with hot water storage tank in the airing cupboard...
  12. S

    cold bathroom radiator

    do i have both rad valves open fully then? And why would the downstairs and the other 3 upstairs rads be all nice and hot and not the bathroom one? Thanks.
  13. S

    cold bathroom radiator

    Hi, Merry Christmas and hope someone can advise........ I had some work done in the bathroom and the bathroom radiator was removed without draining the system and then refitted. Now it stays cold/cool. The pipe to the left of the radiator is very hot but the radiator itself and the pipe...
  14. S

    Ferroli Sigma 40-60 boiler

    ferroli engineer came today and replaced pcb free of charge. fingers crossed it remains working ok now !!!!! :?:
  15. S

    New bathroom - which sort of toilet???

    Have had a re-think and like this one from MFI....... http://www.mfi.co.uk/mfi/FinalProduct.asp?CT=/4020/YourBathroom&CT=/YourBathroom/BathroomIdeas&CT=/YourBathroom/BathroomIdeas/TheBathCompany&CT=/YourBathroom/BathroomIdeas/TheBathCompany/Lena&CT=*&SKU=LEN2001 Seems to include all things...
  16. S

    New bathroom - which sort of toilet???

    Am buying a new bathroom suite. The Mrs wants the basin and toilet to be in adjoining vanity units - hence only the toilet pan will be visible and the cistern concealed. It is this one...
  17. S

    Ferroli Sigma 40-60 boiler

    update...... i tested the electrics on the boiler...... turned the hot water stat up which in turn triggered the motorised valve to turn which in turn triggered the boiler to turn on. using basic electric testing prong thing from B&Q it showed Live at the permanent live, the switched live but...
  18. S

    hot water circulating pump "off-delay" relay switc

    PCB would be for a Ferroli Sigma 40-60 boiler. Any idea?
  19. S

    hot water circulating pump "off-delay" relay switc

    Can anyone advise if this will work?? http://www.tlc-direct.co.uk/Products/EK320A.html http://www.tlc-direct.co.uk/Technical/DataSheets/Elkay/EK320A.pdf Thanks.
Back
Top