Search results

  1. sparkymarka

    PIR swap

    1.6 fast blow ..,.
  2. sparkymarka

    Alarm Wiring, HELP!

    Delta bells don’t ring when you first connect them … only after closing micro switch , then opening it for first time , don’t forget to move the bottom battery link
  3. sparkymarka

    PIR swap

    Check these fuses you need to remove them
  4. sparkymarka

    Alarm Wiring, HELP!

    As below
  5. sparkymarka

    Texecom smartcom cloud led flashing

    Have you tried to request an app code from the control panel ?
  6. sparkymarka

    PIR swap

    Ok Red to + on new sensor Black to - on new sensor Green to T White to other T And blue and yellow to the NC ( either way is ok )
  7. sparkymarka

    PIR swap

    Ok at an educated guess set multimeter on DC ….put probes on the red and black wired terminal ..You should if correct have 13.8v dc
  8. sparkymarka

    PIR swap

    Well…looking at that …there is no power connected to the pirs ….do / did they light up ? If so there got to be a junction box somewhere or the power is linked to keypad / bell ….bit of a bodge job …. You are going to need a multimeter …
  9. sparkymarka

    PIR swap

    Look inside control panel / post pictures That will tell us what colours to use
  10. sparkymarka

    Accenta8 Alarm - Dead or Alive?

    Defaulting the panel is normally the last resort and 9 out 10 times it won’t solve the issue
  11. sparkymarka

    Accenta8 Alarm - Dead or Alive?

    Have you tried pressing reset ? ….panel lid needs to be on
  12. sparkymarka

    Accenta8 Alarm - Dead or Alive?

    What’s coming out of the battery leads ( battery removed ) ….should be 13.8v dc ….also check aux volts …and keypad supply volts at the panel …they should all be about the same ….battery charge resistor looks ok
  13. sparkymarka

    Accidentally factory reset premier elite 24

    Have you tried 5678 first?
  14. sparkymarka

    Scantronic 9800 False Alarm

    On a average cable run ( depending on quality of cable ) you a should be looking at 1- 3 ohms on each pair
  15. sparkymarka

    Scantronic 9800 False Alarm

    Remove the red connected to the pcb .. you will now have 3 pairs of wire ….starting at the red you disconnected and the connector block measure this , now measure at the two connector blocks , and finally the last connector block and the yellow still in the pcb
  16. sparkymarka

    Scantronic 9800 False Alarm

    Remove one leg from the zone then measure each pair with a multimeter set on ohms ….if one pair is very high that’s possibly where the issue is
  17. sparkymarka

    Door

    Have you tried powering down ….move the jumper to the short position ….power back up ? Looks like a cut down version of the CBB Keypad ( less relays ) email CDVI …it’s got to be 19 years old looking at the date code …
  18. sparkymarka

    What CCTV setup do I need?

    Pyronix battery cam 2…..with SD card ….no power required ..re charge every 3 months or fit solar panel kit ….no need to re charge So you can fit at low level …..or Cctv with dvr … blank off the neighbours side in camera settings
  19. sparkymarka

    Door

    The bewator K42 was like this ….it had no programming code as it is done via jumpers …. Still available
  20. sparkymarka

    Door

    No ….
Back