Search results

  1. sparkymarka

    Help with programming a new CAME 840CF-0020 handset

    Download the manual …. But in short form You would hold down program until a green light comes on …. Press the call button on the panel go to handset , with the handset off I think press the door release ….its then programmed , there are slight differences with different models , came / BPT...
  2. sparkymarka

    Texecom connect / smartcom issue

    It’s part of the check list on the V1 to V2 upgrade flow chart…
  3. sparkymarka

    Alarm Wiring, HELP!

    Put a link in zone 7 … set system , activate each device one at a time and write down the zone number
  4. sparkymarka

    Sat dish - RF reflective coating

    Buy a torch ….!
  5. sparkymarka

    Dvr reset password

    Best of luck
  6. sparkymarka

    Dvr reset password

    Google it ….mutiple “ sellers “ to be honest just a generic dvr re badged to various other re sellers … probably not worth the time ..just replace it …
  7. sparkymarka

    Hikvision Doorbell Camera

    That’s not a POE switch ….as per photo …it would have PE in the part number not just E
  8. sparkymarka

    Gardtec 300 Query

    Zone 1 is activating …
  9. sparkymarka

    Hikvision Doorbell Camera

    Does it need power ? Poe or 12v supply
  10. sparkymarka

    Scantronic ion-160 to ion G3MM - alarm triggers but nothing in log

    But you stated …to start with ….it goes off when it wasn’t set …just sounds like a failing contact if it chimes for not reason ….plus if it’s entry maybe it’s setting off the alarm and it’s been turned off before it’s gone into full alarm ( pre alarm ) this would set off internal sounders but...
  11. sparkymarka

    Moving NVR

    You would have to fit a POE switch at the utility or a kvm at the utility if you have a spare cat 5 to the lounge from here
  12. sparkymarka

    Night Storage Heater Electrics

    They may have ……13 Years ago …..
  13. sparkymarka

    Loft Power

    Maybe they only had 1.5 mm cable …
  14. sparkymarka

    Data Cabinet Wallmount

    I would go with the ply option making sure it’s attached to more than one stud …
  15. sparkymarka

    Accenta8 Alarm - Dead or Alive?

    And what was the issue ?
  16. sparkymarka

    Pyronix comm fault

    Take front off panel …it will go off …enter code …unplug the power supply it pulls off ..open battery compartment unplug battery ….wait 30 secs ….plug battery back in , plug psu back in , put front back on …enter code , then yes to reset ….wait to see if time corrects itself …if so it’s re...
  17. sparkymarka

    PIR swap

    They may have changed them on the later ones , they used to be 1.6 fast blow on the older ones
Back