Search results

  1. sajeel

    Data and telephone through single cat 5e cable

    Hi rj45 cat5 uses only wires pins 1,2,3 and 6 for all speeds if you are referring to gigabit then most infrastructures dont have a backbone to support full gigabit it is for servers and fibreoptic networks. Therefore you can have from one wire, 2 x rj45 network points or 1 x rj45 network...
  2. sajeel

    Honeywell Galaxy 2-20 - Engineer's Code

    if memory serves me correct the master code allows reset of engineer code you can get manual from uk panels (i am not on commision lol) i always get a manual form there when i am stuck sign up to frum and post in manuals section if you cannot find.
  3. sajeel

    Meter registration

    ofgem is the meter approve by the dno, i know i am responsible for wiring after that, but this is a new build flat, coming off three phase, so as supply is dead and no meter fitted, i thought it would be quicker to purchase one from here...
  4. sajeel

    Meter registration

    Hi, What is process to register new meter ofgem approve to supplier, if fitted to new building on dead supply ?
  5. sajeel

    Joining SWA

    yes you can use a resin repiar kit like the one below http://www.tlc-direct.co.uk/Products/SWJK2.html
  6. sajeel

    Installation of oven and gas hob

    thankyou EFLImpudence for reminding me regading 16a mcb as it is radial circuit.
  7. sajeel

    Installation of oven and gas hob

    2700 / 240 = 11.25 so 2.5mm te would do however i would 4.0mm te or 6mmte as this will allow you to carry 32a using 4mm or 40a using 6mm allowing for future upgrades, the wire should be radial, run straight from consumer unit, into a isolator and then into socket or spur.
  8. sajeel

    Enabling printing via router.

    USB prnt server will put your printer onto network and allow you to print independent of pc's and any os is not a problem you to print to ip address and install driver on each pc.
  9. sajeel

    Cheapest chain store selling electrics

    Toolstation Screwfix QVS Direct TLC Direct You can google for websites and prices.
  10. sajeel

    electric distribution

    The meters used will be private, current supply is three x 100a fuses, the load for flats will be fused at 60a each, the outer house and shop will be 100a fuses. consumer in shop will be three phase, the rest will all be single phase consumer units.
  11. sajeel

    Bathroom bonding

    if consumer unit is rcd, and the mains for gas and electric are bonded by 16mm earth wire to consumer unit, then supplementary bonding is no longer required. You can choose to have supplemetary bonding if you wish to do so. Hope this answers your question.
  12. sajeel

    electric distribution

    Inlet of three phase, shop on ground floor with outer house, 2 flats above feeding off three phase, my suggestion to split is to use 6 way distribution board by ryefield. Then feeding into fused isolator and then relevant meters. I would split this way Inlet = 3 phase 3 ways to shop 1way to...
  13. sajeel

    Manual needed for modern alarms series 1000

    i have manual for series 1000 please pm your email and i will send to you, sorry for delay.
  14. sajeel

    Faulty Intercom

    Thank you OwainDIYer for going in to detail on wiring configuration.
  15. sajeel

    Faulty Intercom

    There are normally for wires, 2 for door latch and 2 door for audio, you need to identify these wires and then you should be able to fit another handset. hope this helps.
  16. sajeel

    Faulty Intercom

    Hope you find fault, post a reply or pm me should you need any more help.
  17. sajeel

    Faulty Intercom

    to test wiring you can power down first join two wires such as green and yellow at bell unit and then measure using a multimeter on resisitance you should get a value of around 0 at green and yellow on the station in your flat, obviously your colours will be different but there should be four...
  18. sajeel

    Faulty Intercom

    i cannot give too much advice apart from check all wiring from buzzer to station, if you are in london i can araange a free visit to check for you and offer a solution or repair. pm me if you want
  19. sajeel

    iphone cctv?

    hi, you need to open router for your dvr, also you need eithier static ip or dyndns, however all the dvrs ive ever installed only support internet explorer therefore you need a jailbroken iphone and need to use user agent faker...
  20. sajeel

    Advice on a cctv dvr please

    you have two ways to do this, one is to use a pc based dvr and network or the other is stand alone dvr connected to internet, as with remote viewing on mobile you need a dvr with 3g suport and normally its too slow and too small the dvr boxes i sell have internet explorer suport and you will...
Back