  1. S

    Structural full width lintel - Help please

    Hi, No, no others have an extension.
  2. S

    Structural full width lintel - Help please

    Hi, Thanks for the reply. Yep, appreciate I will need a structural engineer to size, but if the cost is prohibitive then it isn't really worth doing anyway. The house is standard construction, concrete block and brick. Thanks again Sam
  3. S

    Structural full width lintel - Help please

    Hi, Thanks for reading. I am proposing a rear extension which will be the full width of the rear of the ex council house. The existing structure appears to have a full width (6.6 metres) concrete reinforced lintel which spans the building, with a wall in the middle. Picture attached. I've done...
  4. S

    Party wall act and footing depth

    So does the party wall act not come into force providing I don't knock the existing wall down, ie I could leave a 10mm gap and not require a party wall agreement? The footings might be the only issue I guess? Can i dig below this party wall fence footings without the agreement? Thanks...
  5. Untitled

    Untitled

  6. S

    Party wall act and footing depth

    Thanks for the reply. Could you clarify, is the 900mm from bottom of trench to finished floor level or to natural ground level? The party fence wall issue still lingers as the existing wall with the troublesome neighbour may cause issues. Currently, behind the femce I put up is a 1000mm...
  7. S

    Party wall act and footing depth

    Hi all, Thanks for the replies I did not see. All a little bit over my head if i'm honest. Anyway, I have today dug a test hole as recommended. I have some photo's and would appreciate your input. The distance from the top of the existing concrete footing to the finished floor level...
  8. Untitled

    Untitled

  9. Extension

    Extension

  10. S

    Party wall act and footing depth

    Yes, Unfortunately these kind of figures would make the whole project unviable. Mainly due to the restricted value the work would add to the property. Personal circumstances mean I am unable to move (self employed) and as my family gets bigger we are quickly outgrowing the house. On the...
  11. S

    Party wall act and footing depth

    Thanks very much for your help. Unfortunately, the footing will need digging by hand as you won't get a machine up the steps! Annoyingly I have a neighbour who is a machine driver also!
  12. S

    Party wall act and footing depth

    Hi, Thanks again for replying. With regards to the render, I was thinking along the lines of maybe a capping stone on the existing party wall fence to effectively block off the void? Not sure if that is a no no or not? If not, could you suggest an option? Not sure on ground type...
  13. S

    Party wall act and footing depth

    Hi, Thanks for the reply. The 'chat' is what I am worried about. We have a long list of disputes under our belts, most caused by them seemingly not being able to be reasonable. The last dispute was due to one of my vans being parked about 4 inches across their drive for 2 hours whilst...
  14. S

    Party wall act and footing depth

    Hi, i'm planning an extension on my mid terrace house at the rear of the property. The plan is for it to be the full width of the property, or as near as. On one side there is a wooden fence (mine) which can be moved and no issues with neighbours. The other side is a little more...
  15. S

    Vaillant Ecotec 831 - rainwater ingress

    Vaillant flues have the angle built in to the terminal. If it's just the one section it should be pretty much level. Had a lot of issues like this over the last year or so mainly due to incorrect angle of flue when installed. I'm surprised all the manufacturers don't have the air intake...
  16. S

    Wall hung wood burning stove - flue question

    Your installer is right. 150mm max horizontal length. If you come off the top then you'll need a length of flue 600mm before the first bend then 45 through the wall.
  17. S

    cement taking ages to go off!

    Just to let anyone else know, the render dried off fine over night, I was panicking over nothing. I applied the final coat this morning with no SBR priming and it all went well. Just going to wait for a few days until the render is completely dry now so I can skim it with some multi finish...
  18. S

    cement taking ages to go off!

    Hi joe90; I think it was about 10 to 1 yeah, it actually didn't state the ratio on the tub so I to a guess on the side of caution in case to much would stop it bonding all together. It's the first piece of internal rendering I have done so normally I'd just drench it with a hose if...
  19. S

    cement taking ages to go off!

    As per another thread I started, I have been rendering a wall after damp in my brothers house. Yesterday I put up the first scratch coat, SBR'd the wall first with 2 diluted coats approx 10 - 1 , then proceeded to apply the render. The wall was obviously still very porous as I had to work...
  20. S

    rendering/plastering after damp treatment

    Thanks for all the replies, sorry I have been a little tied up with other things so couldn't reply earlier. Well my brother had the damp proof injection carried out anyway. The next task is for me to have a go at rendering the wall. The damp course has been installed fairly low and the wall...
Back