  1. M

    Carbon Monoxide Alarm

    Flame on a gas hob are normally blue.
  2. M

    Method or madness in this CH installation?

    What’s the purpose of the 3 port valve, Combi boilers don’t normally have motorised valves at all.
  3. M

    Trv valve off but radiator not cooling down

    Maybe a silly question but you are turning them clockwise to turn off?
  4. M

    Bang when central heating shuts off

    Pipe work not secure somewhere is possible.
  5. M

    Has wrong kW rated boiler been fitted

    There should be a label on the boiler stating the model and GC number.
  6. M

    Should I replace my ideal Mexico super 2 boiler with a heat pump

    It’s very likely that you will need not only the heat pump but also a new hot water cylinder, all radiators replacing and pipe work modifications so expect the HP bill to be a lot more than just a gas boiler replacement.
  7. M

    Draining an indirect cylinder to change a faulty zone valve

    Is it the valve sticking in the valve body or the motor sticking in the valve head? If it’s the valve head then that can be changed without draining the heating circuit.
  8. M

    Danfoss hard wired thermostat problem x 2 in new build home with Ideal combi boiler

    You would have to modify the zone valve wiring as well or just disconnect the valve from the wiring centre completely so there is no call for heat.
  9. M

    Pump overrun while valves are shut

    The only way to do what the OP wants is to replace the CH motorised valve with a normally open valve to give a PDHW setup but without the ability to change flow temps in the boiler.
  10. M

    Boiler suggestion to replace potterton suprima 70

    Any quote needs to be based on the heat loss survey, I'm surprised BG can state the boiler size without having the heat loss figure.
  11. M

    Sizing rads and lower flow temps...?

    The dT of 20c is only for a flow temp of 70c. The lower the flow temp, the lower the dT. My condensing boiler generally runs at a dT of 10c to 15c with a flow temp of approx. 60c.
  12. M

    Water leak under toilet tank, is there a special spanner/wrench for this?

    Be careful not to overtighten, it is easy to go to far and make the leak worse.
  13. M

    Drop across radiators

    I wouldnt get to hung up on getting the delta t to 20c, not many modulating boilers manage that at 60c flow. Just get the return temp as low as possible.
  14. M

    Pipe Thermostat to turn on secondary pump

    The orange wires should all be connected together so that any zone valve can call for heat and turn on the boiler and pump.
  15. M

    Pipe Thermostat to turn on secondary pump

    I think its best to keep it simple. My suggestion is simple and free, just connect the additional pumps LNE to into the wiring centre and connect the pump live to the terminal in the wiring centre where the orange switched lives terminate from the motorised valves. So when the room thermostats...
  16. M

    Pipe Thermostat to turn on secondary pump

    If you have a 2port motorised zone valve for the CH you could feed the pump from the switched live of the valve.
  17. M

    What are my options, to set room temperatures?

    If the Nest heat link is connected to the boiler then I can see that it might work but Nest can’t communicate with Wiser. Wiser is a pretty good system, it has a few foibles. I don’t use the Wiser TRV’s anymore as I have gone to a more open heating system.
  18. M

    What are my options, to set room temperatures?

    Only Drayton Wiser TRV’s can communicate with the Wiser hub to fire the boiler as it is a closed system.
  19. M

    Internet speed - WiFi v wired.

    The TV Ethernet connection is probably only 100mb whereas WiFi can go much faster on a 5g WiFi connection. You are also limited to whatever your broadband speed is.