  1. ollski

    Banning gas boilers

    I remember a meeting at bg in 2008 telling us this would be law in 2010
  2. ollski

    Recommend me a deeper rad valve

    All a bit more work than I fancy, just want to bung it and hacksaw under the old olive and replace with an 8mm valve rather than adaptor.
  3. ollski

    Worcester 35CDI - Constantly On dispite Eco button - Costing me a fortune!!

    I’d be checking external controls then first
  4. ollski

    Worcester 35CDI - Constantly On dispite Eco button - Costing me a fortune!!

    You sure it’s the fan?, faulty pcbs commonly keep the pump running 24/7
  5. ollski

    Recommend me a deeper rad valve

    Is there a brand designed a bit longer / deeper than normal so I can cut the existing leaking microbore connection under the crushed olive and fit another valve that will seal even with no movement in the pipe?
  6. ollski

    Drayton ZA5 actuator head alternative

    This is true, it’s the reason the annual service on the unvented cylinder has one of the checks dedicated to manually making and releasing the spring return valve to ensure it does
  7. ollski

    Anyone familiar with ICQ?

    Cheers mate, can’t even nail the name!. Water intermittent, operates flow switch calling for water at 55 degrees but just sits at 22 and doesn’t modulate up...ok for heating if just a little slow as if a filter may be blocked somewhere
  8. ollski

    Anyone familiar with ICQ?

    got a fault on a simplicity 30 and not sure what it’s a clone of. Anyone familiar with them?
  9. ollski

    Drayton ZA5 actuator head alternative

    No. Sorry. Honeywell is a better lasting valve but you need to replace complete.
  10. ollski

    Leaking Baxi Solo 18 HE

    I expect so...are there lots of dry white watermarks on the rhs panel in the combustion chamber?
  11. ollski

    BG 360 RD1 (Ideal Classic) fan replacement

    If you use zx1-c60 oil you won’t even need to strip it. 90% dry bearing rescue for me.
  12. ollski

    BG 360 RD1 (Ideal Classic) fan replacement

    You’d need to flue gas analyse the emissions to ensure safe operation following replacement. It’s definitely rgi as it’s actually rebuilding the flue
  13. ollski

    To all you GasSafeists

    Although if I were to be pedantic he would have no choice not to walk out of a dangerous appliance in a house if refused permission to isolate
  14. ollski

    Gas Safe Engineer

    It’s not always a case of training a competitor though, if you train up a decent lad why would he want to move on if you provide him a competitive salary?. There is a shortage of good gas engineers although Bg recently lost a thousand or so who will be adding to the pool. It’s very hard to...
  15. ollski

    To all you GasSafeists

    Dan’s spot on. If it failed you would be requested to do another one when the remedial work was carried out. There is one landlord inspection a year with advice issued where required.
  16. ollski

    WB Greenstar 18Ri keeps locking out.

    To be fair if your fan speed test was in the acceptable range there is no need to clean out the heat exchanger.
  17. ollski

    Ideal Response 80 recommisioning problem.

    Might as well open the prv when you recharge the vessel...it’s recently discharged anyway