  1. U

    help cold radiators

    if its cool at the bottom and hot at the top, it means you have sludge in the system, if its really bad it could be this thats affecting your system
  2. U

    pop up waste leaking

    is there anyway to raise the waste ring so i can add the sealent without removing/unscrewing the pop up waste which i am unable to do?
  3. U

    pop up waste leaking

    thanks for the help chrisR, looks like thats my only option other than removing the vanity unit which would be a real pain.
  4. U

    pop up waste leaking

    Hi I have a small leak from where my pop up waste enters the bath, the water seems to be leaking by the foam seal, it generally begins to happen when the bath is half full. I have replaced the rubber o ring on the plug but the leak is still there. My next route was going to be to silicon...
  5. U

    Poor flow from hot and cold

    Hi I have a very poor flow coming from my hot and cold taps on my indirect gravity fed system. (Bungalow) The tank is located in the loft space and can be raised some more but only by about 3 ft, will doing this greatly improve my flow rate? The hot and cold to the bath are both fed by 22mm...
  6. U

    Recruitment

    I dont suppose you take on trainees by any chance?
  7. U

    leaking pan connector

    hello, I have just fitted a WC and it is leaking from the panconnector where it seals onto the pan. The pan connector is brand new. The toilet is an off the shelf one from B and Q, I was wondering whether it could be the actual connector or the moulding of the pan that could be at fault...
  8. U

    installing cloakroom suite

    cheers guys, wasnt sure whether just turning it off was ok, but ill play it safe and turn it off anyway thanks again
  9. U

    installing cloakroom suite

    hi im new to this so any help would be appreciated I am installing a cloakroom suite at the moment, the toilet is not a problem as there is an isolating valve where i can shut off the cold feed to it. The basin is a bit differant, their is no isolating valve on either the cold or hot water...
  10. U

    Caption Contset 30

    'Bloody plumbers, they forgot to install the toilet'
  11. U

    Caption Contest 34

    'This is gonna take forever..............'
  12. U

    Asda - their bogofs are bogging off...

    BOGOFS are used to attract customers into the store. However if you go shopping with the intention of buying for instance 2 bottles of coke, becasue its BOGOF you will lose the profit you stood to make on the second bottle, so their is a slight profit loss on the purchase. Now i know that...
  13. U

    Looking For experience

    thanks for all the replies guys, i really appreciate you having taken the time to answer me, and you have given me alot to think about. My previuos job was as a retail department manager, so im used to working to tight regulations etc, and i tend to agree with paul barker, the more regs they...
  14. U

    Looking For experience

    Hi, im currently looking to get some in the field experience in the trade, with a qualified and experienced plumber. I have completed a training course consisting of both theory and practical work and have gained a OCLN certificate in plumbing as well as water regs. Im well aware that I still...
  15. U

    mixer shower

    thanks for the help softus, ive decided to change the cold water tank in the loft while im at it due to the poor condition its in so Ill reroute the pipework while im at it, again thanks for the help
  16. U

    mixer shower

    thats correct softus, my only worry was that the instructions said to come direct from the cold water tank to the shower by a direct pipe. I should have also said that the pressure in the existing set up is fine, and the only reason im changing it is because im fitting a new suite.
  17. U

    mixer shower

    thats correct softus, my only worry was that the instructions said to come direct from the cold water tank to the shower by a direct pipe. I should have also said that the pressure in the existing set up is fine, and the only reason im changing it is because im fitting a new suite.
  18. U

    mixer shower

    I am about to order a thermostatic mixer shower but after reading the instructions I have a few questions. It syas that the hot feed should be taken from the vent and draw off point from the hot cylinder and the cold should be taken directly from the cold feed tank. After checking the existing...