  1. C

    Carrycase for fluke.

    Wonder if any of the Site regulars can help me.I have a Fluke mulitmeter 83 series and i am trying to purchase a carrycase for it. I have tried RS but found nothing on the RS website.I have been on the Fluke.co.uk site and found the part number. It is a softcase C90.,but they do not sell...
  2. C

    16mm earth

    The electrician had to the testing on the bathroom as he had installed 3 x downlighters.The bathroom company would not let me do it as i was not a recogised electrician.He did Part P the installation and we got a certificate 3 weeks later. I have done 16th many years ago ,but when the lads...
  3. C

    16mm earth

    It is clamped on ,and when i moved in 7-8 years ago the nice man from the electricity board came to inspect the meter and fuse etc.If it had to be sweated/soldered on surely he would have told us then. My bathroom was part-p inspected 1 month ago and the lad told me to change the earth then...
  4. C

    16mm earth

    I have an earth wire on my system which might possibly need upgraded. My main cable comes into the house then the earth wire is taken off a clamp off the armour on the cable.This then goes to an earth junction box obviously was put in by the electricity board many years ago.From this junction...
  5. C

    main fuses

    No mate its definately 40A.They funny thing is southern electric whom are now my supplier,i rang them and they said they would send a elecky round,thought that was kind,but yes at my expense. The main service fues was fitted when the cable was installed and was 40A,they must not of had elecky...
  6. C

    main fuses

    Thanks i never thought about that one ,but i think the brand new consumer box would a dead give away. I will remember it well thanks.
  7. C

    main fuses

    I have had it out to check it.Surprising the fuse is not tagged ,wire locked crimped or ,there is no nice colourful stickers on it.I did take the load off the supply before i removed it. I will contact the supplier i check with them,they will probably tell me to get a elecky in.? Thanks lads.
  8. C

    main fuses

    Probably an old one to the site regulars,but i have just looked at the main incoming fuse,and found its an old 40amp one.Trouble is the house was wired by the council and a new 100amp consumer box was installed.House is now private. Should this fuse be uprated by the electrical supplier,i take...
  9. C

    9.5kw showers

    Thanks Sparky 123, I went offshore in early nineties because the domestic game was quiet and the money wasnt too good.I did the 16th but that was a doddle compared to this Part P classification.So as you can guess i am a little losted when it comes to knowing what you are allowed to do and...
  10. C

    9.5kw showers

    Thanks, Cheers i understand what you mean now.Help appreciated.
  11. C

    9.5kw showers

    The old cooker circuit is wired with 6mm,and looks as though it has never been used. The shower circuit is wired with 10mm with all the amenities being earth bonded with 10mm.I have been told to wire from the earth incoming to the new box in 16mm???. When i buy the new box could i wire the old...
  12. C

    9.5kw showers

    I have just had a 9.5kw shower plumbed into my bathroom and it has been connected to my old council fitted MK box which is approximately 12 years old.I bought an RCBO 32amp ,but then realised that i should have installed a 40amp ,i think.??? As i had a lot of trouble trying to fit the RCBO into...
  13. C

    re-training

    I ve got all the C&G 1,2,3 and 4 electrical and electronic craft studies .Though i have done the 15th and 16th edition in 1994. The C&G qualifications are electrical plant and did not have a number ,like now they are called 232 etc.They were done in the period 1983 -1987,we used to do proper...
  14. C

    nissan tino

    Purchased a nissan tino last year after i had one for 3 years and no problems at all. Within 3 months my wife noticed that she could not get the car open with the VOB,switch on the key ring. I tried but no luck.Eventually got the garage involved they could not get the car open straight way...
  15. C

    re-training

    adavice needed please. I am a 39 year old marine electrician who is trying to get back onshore. I did the 16th edition years ago and did hold the JIB maintainance card until they changed the rules and i had to give it up. What qualifications would i now need to get back onshore and wheres...
  16. C

    zanussi condenser dryer TC 481 W

    Thanks i did the obvious and tried to pass the belt under the wheel.All working now thanks.
  17. C

    zanussi condenser dryer TC 481 W

    My main belt has snapped after six hard years,so it has done well .I have got the new new belt around the drum but cannot work out how it goes around the motor pulley wheel.The users book does not show how to change this belt either. Help with a site or advice appreciated.
  18. C

    Noisy Vokera ESC

    I had the same problem here about two years ago.Got the experts in and they found it was the flue.Where the flue went through the loft a coupling was broken.Point to remember here is that the flue on this system is a pipe within a pipe,if the two gases come together it crates an awful racket.I...
  19. C

    vocera linea 02 lockout

    With reference to my last posting about when using the shower(when the heating was on and it goes cold every so often).I can tell you if you turn the shower off then back on it does come back,the hot water does.I do have combi shower(mira). Another small thing happened this morning,i put...
  20. C

    vocera linea 02 lockout

    I do also have a small sensor which fits in the pipework as a spare,but i dont know whether i would have to drain the system down to fit it.Most of the sensors i work with are usually fitted into pockets. The book or parts manual shows a thermistor and a saftey thermostat which looks very...