  1. D

    Depression in floorboards - 10mm across 1.8m span - leveling for laminate floor?

    I am really reluctant to lift the floorboards more. The area to be 'filled' is 1.2-1.4m wide but to get under to shim or sister I would have to be lifting 3-4m long intact boards. They are old, will likely split, all the T&G will break. At least with wood strip, I can lay it down it sections...
  2. D

    Depression in floorboards - 10mm across 1.8m span - leveling for laminate floor?

    @JobAndKnock what if I ever need to get under the floor, repair wiring or heating pipes? That approach would be a nightmare for it. I think Im going to have to try the furring strip approach. Pulling up floorboards to shim the joists will likely result in breakage. If I lay down the strip I can...
  3. D

    Depression in floorboards - 10mm across 1.8m span - leveling for laminate floor?

    In order to shim the existing joists under the floorboards, or sister the joists completely, I would need to lift alot more full length floorboards. They are mostly nailed down with the tongue& groove still intact, except for in some places where wiring or central heating pipes have been put...
  4. D

    Depression in floorboards - 10mm across 1.8m span - leveling for laminate floor?

    Hi all, Upstairs bedroom, wooden floorboards. Due to the way the floor beams have been constructed near to the chimney breast, a section of the floor is dipped by a max of 15mm in one area, but typically more like 5-10mm, over a span of around 1.8m. I have had the floorboards up in a couple...
  5. D

    What are these hinges and where can I get them from?

    Hi all. My girlfriend's Dad asked if I can find these hinges. He is Polish and makes cabinets but can't get them in Poland he says. Any ideas? Thanks.
  6. D

    What fixings to screw 6x2 beam to brick wall?

    Overall about 3-4m wide x 3m long. But its awkward - my house has a few internal solid brick walls that I am planning to take advantage of. So on one end there will be a ledger beam screwed onto the party wall, then the joists will run perpendicular with the other end of them sat on top of an...
  7. D

    What fixings to screw 6x2 beam to brick wall?

    Loft boards and light storage.
  8. D

    What fixings to screw 6x2 beam to brick wall?

    Thanks which size? Timber will be 50mm thick so Im guessing at least 100mm length but what thickness?
  9. D

    What fixings to screw 6x2 beam to brick wall?

    Hi I'm going to be screwing a 6x2 beam flat to a wall to support some further joists running perpendicular. What fixings should I use to screw this into a solid brick wall please?
  10. D

    Rules for boiler in cupboard

    There are about four airbricks in the kitchen, I don't think we need that many, and its making the house colder. There is currently a gas oven, so I won't do it until we do the kitchen refurb and swap that for an electric oven. As its an older house with solid walls we get quite a bit of...
  11. D

    Rules for boiler in cupboard

    Oh sorry, I just was asking whether what Im planning to do is ok. And also being unclear on why a warning sticker was attached in the first place.
  12. D

    Rules for boiler in cupboard

    When I moved into this house there was a sticker on the boiler, placed there at some point in the past by British Gas, that said the install was non-compliant because the boiler was in a cupboard with no ventilation. However there is a whopping airbrick at the back rear of this cupboard...
  13. D

    Where can I get these lockshield valve caps from?

    Yeah the link works but then try to add to basket it errors. I'll email them. I emailed another company that had the pegler valves and they came back to say that was old picture and no longer stocked.
  14. D

    Where can I get these lockshield valve caps from?

    I saw those yeah, don't really want blue lettering all over the top of my radiator valves though.
  15. D

    Where can I get these lockshield valve caps from?

    Tried searching for those terms plus more, I'm not finding replacement caps for sale anywhere.
  16. D

    Where can I get these lockshield valve caps from?

    Hi all, Looking for replacement caps for lockshield valves in my house. The existing ones are labelled BS2767-10 Brand Centre and have a square fitting with a securing screw, and on the valve itself seems to be some sort of plastic sleeve which I can't get off (at least, didn't want to try too...
  17. D

    Range rating, modulation and manually setting the CH temperature question.

    Interesting read. I too am wondering how range rating would be influenced by, or influence, the heating flow temperature dial. Is it possible a boiler that is range rated too low could not reach the higher heating flow temperatures on the dial in very cold conditions? Also how would one tell...
  18. D

    Expansion vessel failure

    Just an update the pressure on running now seems to be very stable, only rising by 0.2-0.3 bar from cold to hot. I haven't run the system in anger yet though its not been cold enough, boiler temperature only set to setting 2 on the dial, so I imagine if the water is hotter I'll get more of a...
  19. D

    Expansion vessel failure

    Ok system running and up to temp on boiler setting 2. Pressure very stable, climbed to just over 1 bar. Will switch off now and let it settle before checking if any radiators need bleeding. I've also tied a bag over the prv outlet to check for any drips.
  20. D

    Expansion vessel failure

    I can, its an integral filling loop with a key insert thing. Will do it now.