Search results

  1. N

    warm roof insulation

    hi, I have just installed 90mm of insulation between the rafters and am about to put 70mm on the underside of them, I am unsure as to what is the best way of fixing this tightly to the rafters?
  2. N

    roofing question

    done job, the guage was from centres not as I originally thought between batten. DOH!! as for size of batten, it says in the guide what size of batten is required which is 38 x 25
  3. N

    single skin wall insulation

    unsure as to if there will be a problem with damp as until recently the wall was external to the main building
  4. N

    roofing question

    I set it out on the roof using a baton cut to 293 for the spacing. Baton size for tiles I have used is 38x25
  5. N

    single skin wall insulation

    baten and thermaline board as i am guessing this will save me more space than other methods
  6. N

    roofing question

    I am using a redland regent tile for a roof pitch of 14 degrees, according to the guide the tiles require a headlap of 100 with minimum baten spacing of 293mm however having set this out it only gives me a headlap of 75, what difference will it make if I decrease the baten space to give me the...
  7. N

    single skin wall insulation

    thanks, are there regs relating to thickness of insulation, gap between wall and plasterboard etc.
  8. N

    single skin wall insulation

    Hi guys, part of my property I have just extended into has a single skin external brick wall which I need to insulate trying to retain as much space as possible and complying with building regs, having read many different threads on this issue there doesn't seem to be a defining answer, can any...
  9. N

    lead detail

    thats great, many thanks it is just as you have described so will run soaker up into chase etc.
  10. N

    lead detail

    looking at the link you have posted I think you might of misunderstood my admittedly bad description.....so I will try again. there was a continuous lean to roof all at the same hight so no problem with the lead flashing chased into brickwork..Now I have extended half of the back of the property...
  11. N

    lead detail

    thanks, is it possible to buy a preformed saddle as I have neither the tools or experience of welding
  12. N

    lead detail

    roof running into a gable. How does the lead running along the top of the roof get dressed into gable which will have stepped flashing?
  13. N

    fitting spindles

    I wish. No it just has a single board running full length and has never had spindles.
  14. N

    fitting spindles

    Currently we have boarded stair rails which we would like to replace with spindles, what is the best way to go about this so as not to compromise it's required strength.
  15. N

    mono pich roof insulation

    Hi again, roof structure, rafters, purlin ect. now all in place so time to think about insulation. I have decided to go for a vaulted ceiling (warm roof) and am aware that it requires 90mm and 40mm celotex or equivalent. I understand the 90mm goes in between the rafters which are 125mm but I am...
  16. N

    mono pich roof

    can joist hangers be used instead of birdsmouth?
  17. N

    mono pich roof

    great thanks for that, does the purlin need to be built in at an angle to match pitch of roof or square to blocks?
  18. N

    mono pich roof

    just one more thing. What bolts would you recommend to attach pitching plate to the wall. pitching plate is 4 by 3
  19. N

    mono pich roof

    Okay, having done some calcs. I do definately require a purlin if nothing else it will keep the building inspector happy. problem is now how do I attach the purlin to the two sloping walls? Sure this sounds silly but I am a complete novice.
  20. N

    Firstly many thanks for your reply noseall, unfortunately my lack of knowledge on roofing has...

    Firstly many thanks for your reply noseall, unfortunately my lack of knowledge on roofing has led to not using correct terminology refering to length and width instead of span? the span is actually the larger dimension 4m so am I right in saying that this alters your response? If so how? I do...
Back