    Worcester HeatSlave Boiler - Sticking Synchronous Motor ?

    Hi I have a Worcester Heat Slave 20/25 oil fired combi boiler. Recently it developed an intermittent fault where it fails to start up when the timer switches it on for Hot Water. It makes an clicking noise, but does not fire the burner or the pump ? I was wondering if it could be the...
  2. W

    Can a RCD be used as an Isolating Switch

    Hi Yes that is correct. I was concerned that if someone assumed what I had initially assumed that the consumer units were interconnected the could get an electrical shock. I am going to place a self adhesive warning label inside both consumer units so that it is obvious to anyone who opens...
  3. W

    Can a RCD be used as an Isolating Switch

    Hi Yes there is a note inside the second consumer unit highlighting that there is an RCD and it needs to be tested quarterly. I take it that the dolly switch can be used as the isolating switch ? Many thanks.
  4. W

    Can a RCD be used as an Isolating Switch

    Hi sorry me again. When it comes to consumer units is it correct to say that you should always isolate each consumer unit individually and not assume that an isolating switch in one consumer unit would isolate everything assuming more than one unit in the same house ?
  5. W

    Can a RCD be used as an Isolating Switch

    Hi thanks I was just worried that if someone flipped the isolation switch to off they might think the whole house was dead which is not the case !
  6. W

    Can a RCD be used as an Isolating Switch

    Hi In my house there are 2 MK consumer units. Upper unit has an isolation switch and all the MCBs are for lighting circuits Lower Unit has an RCD and all the MCBs are for ring circuits. It was installed a while ago. When I flipped the isolation switch in the upper unit I expected...
  7. W

    Diplomat APM 8512 Washing Machine - No Longer Spinning

    Hi I have a Diplomat APM 8512 Washing Machine ( I believe that is a Servis machine ) which is no longer getting up to the full spin speed of 1000 rpm. I have checked and cleaned the filter - in addition the machine drains normally. Machine agitates the drum left and right and spins...
  8. W

    32mm OD Metal Pipe into a 32mm Compression Fitting ?

    Hi Quick question ! I have a metal pipe coming off a basin metal ( chrome ) bottle trap. The OD of the metal chrome pipe is 32mm. Will a standard 32mm compression fitting ( multifit ? ) secure correctly around this pipe ? Many thanks.
  9. W

    Lighting Circuit - Which wire is Live ?

    Hi Gary I have a multimeter. If I disconnect the 2 leads from Common then turn the power back on and measure 240Vac between the 2 wires and neutral then this must be the Live supply ? Cheers
  10. W

    Lighting Circuit - Which wire is Live ?

    Hi I have a ligthing circuit with a 1W switch which has 2 wires running to the Common connection and 1 wire running to the 1W connection. Could anyone tell me which side is Live ?
  11. W

    Please Help - Dimmer on a Lighting Circuit

    Hi I have just fitted a Lutron digital dimmer to a single circuit of which has 6 in number 35W LV halogen lamps fitted to it. The lamps each have a dimmable transformer and all seem to be buzzing ? The dimmer itself is quiet. On the back of the dimmer there is L for live and a symbol...
  12. W

    Diverter Valve on a Worcester Boiler

    Tony At this stage we are not sure. As you know the diverter valve is very difficult to get to in a HeatSlave. We wanted to have all the spares we may need before removing the existing diverter. There is the chance that it is just the powerhead is faulty or the ball valve is sticking and...
  13. W

    Diverter Valve on a Worcester Boiler

    Hi The diverter valve on our Worcester boiler needs to be replaced. The Honeywell part number for the valve is V4044F 1109. I am having trouble sourcing this valve. It is a diverter valve with an auxilliary switch. Could a mid positioned valve ( V4073 ) be wired to operate like a...
  14. W

    Cable Rating to Supply a Hob and an Oven / Microwave

    Hi That's correct. The manjority of the cable runs through the ceiling where it was clipped to the side of the timber joists. The rockwool insulation was then installed between the joists. From what I have read the MCBs should be changed from 40A to 32A which is what the electrican had...
  15. W

    Cable Rating to Supply a Hob and an Oven / Microwave

    Hi My oven has a rated maximum load of 3.7kw and the microwave grill has a rated maximum load of 3.6kW. Total maximum load of 7.3kW. Both are supplied from a single 6 sq.mm cable protected with a 40A MK MCB. The cable length is approximately 12 - 15m long. It has been run clipped to timber...
  16. W

    Commissioning a New CH Pump ( e.g. Grundfos )

    Hi I am sure that have read some where, that when a CH pump e.g. Grundfos is fitted to a CH system ( which is new system or has been fully drained system ) that the pump spindle should be manually rotated before electrical power is applied to ensure that there is water on both sides of the...
  17. W

    Underfloor Heating - Engineered Board or Solid Wood ?

    I am extremely grateful for your help and fast responses. :D
  18. W

    Underfloor Heating - Engineered Board or Solid Wood ?

    I see ! So the engineered boards will shrink less. Does the shrinkage cause creaking ? Sorry to bag on about this - I am most grateful for your help :D
  19. W

    Underfloor Heating - Engineered Board or Solid Wood ?

    Is the shrinkage cosmetic from the point that you can see the gaps opening ever so slightly or will the shrinkage cause creaking ?
  20. W

    Underfloor Heating - Engineered Board or Solid Wood ?

    Thanks Board for board - Say 150mm wide engineering board versus 150mm wide solid wooden board are you likely to get less movement ( and hence less creaking ? ) from an engineered board when the underfloor heating raises the temperature of the flooring ?