  1. Untitled

    Untitled

  2. Garage

    Garage

  3. A

    burying pipes in copper floor

    Underground copper is much thicker than standard copper pipe though.
  4. A

    burying pipes in copper floor

    I once removed a gas pipe that passed through a damp brick wall unsleaved. When it was removed it was like a teabag so your post I'm afraid is garbage.
  5. A

    Gas pipes in concrete

    Before burying a copper gas pipe in concrete my first choice would be a roll of factory sheathed copper, second would be pipe wrapped in denso tape. Wrapped in yellow gas tape? :shock: :?
  6. A

    Four Double Sockets on a 10A Radial.

    Room will be a tv/xbox room for the kids, in the future when they've outgrown it then it will become a spare bedroom so no real increase in load. The only reason I didn't just extend the ring was the fact I had to put cables behind the insulation. Was just unsure on the regs & if LABC may...
  7. A

    Four Double Sockets on a 10A Radial.

    A bit more digging 433.1 looks like 20A it is then.
  8. A

    Four Double Sockets on a 10A Radial.

    Any issues with this? Having done a quick google have read some say minimum MCB size for sockets on a radial should be 20A (some disagree). This is for a garage conversion into a kids play room. Total circuit is 22M of 2.5 T&E. Two sockets will be in an external wall and cables will run...
  9. A

    Oops :@( (Magnaclean Woes)

    Alright Chris, how's it going? :lol:
  10. A

    Expensive Plumber??

    Last time I helped a neighbor out (5 min job). I never asked for any payment. They stuck an envelope through my door with £50 in it that night. Thank fook I don't have neighbors like the OP :lol:
  11. A

    Ferroli

    Don't give your vouchers to the missus :shock: . Save them up to buy o-rings when the pile of ****e is ****ing water out of every connection in the boiler (usually around 9-10 months after it's installed :wink: )
  12. A

    Fault on Ideal boiler

    I was thinking flow turbine on the Logic, but then remembered they are the daddy of all boilers and never have any faults on them :D :D :D
  13. A

    Floor insulation

    It's a heated space above and the external wall is already looking like 70mm kingspan (89mm posts) then 40mm kingspan k18 or a multi layer foil with battens. Either way this brings finished wall surface almost to the window opening so not keen on adding any extra there either.
  14. A

    Floor insulation

    Looking for the best performance for minimum thickness. I'm looking to convert my garage into a habitable space. The floor in the garage is 85mm lower than in the house. Really struggling to find a solution that will avoid having to dig up the floor. Target u value for building regs is...
  15. A

    Cables in an insulated stud

    35mm box. Picture is deceiving.
  16. A

    Cables in an insulated stud

    They most certainly are. Once the sheet of plasterboard is back on there is a partition going up along the line of the steel beam so they will be less than 150 from the ceiling and corner of the room.
  17. A

    Cables in an insulated stud

    Is this ok to avoid having to derate the cables?