  1. N

    Joining NICEIC

    Securespark, i will do that monday but just wanted to mull over things this weekend, and as i've just got in havent had time to ring so thought someone may have been able to help!
  2. N

    Joining NICEIC

    Cheers, but thats were got basic info from, but its not very clear thats why wanted someone to clarify for me
  3. N

    Joining NICEIC

    Aren't they shut right now?
  4. N

    Joining NICEIC

    I recently passed my 2360 part2 then 2381 16th edition, i'm now studying 2391. I wish to join NICEIC domestic installer scheme. When you 1st apply you pay £400+VAT, do you then pay the £340+VAT as soon as you get accepted or the following year? It says you have to show assessor 5 jobs, one in...
  5. N

    6mm Butt Crimps

    To move cooker from rcd side of board to non rcd cos i got feeling thats why it ocassionally trips rcd
  6. N

    6mm Butt Crimps

    Can you get 6mm Butt crimps? I've tried several local suppliers with no luck, TLC Screwfix etc dont supply either any suggestions? Its to extend some 6mm cable by few inch
  7. N

    Supplementraty Bonding

    How do i check that, do i have to lift floor up? Cos its all laminate flooring!
  8. N

    Supplementraty Bonding

    If you did a continuity test between radiator pipe and pipework supplying hot/cold tap at sink in bathroom, and it give an infinety reading, would this indicate that no supplementary bonding was present? Shouldn't they be some type of reading? Shouldn't the radiators be connected with earth...
  9. N

    Bonding

    If incoming water pipe is plastic but water pipes in house metal you still have to bond to metal water pipes, is that correct? But what if there's plastic water pipes in the installation as well and some metal? I kind of mixture, some metal some plastic, do you have to bond to all parts that...
  10. N

    Size of Extractor Fans

    What size extractor fans would i need for a en-suite measuring 3Mx2.5Mx2.4M, and a bathroom measuring 3.6Mx3Mx2.4M? Would 100mm timed extractor satisfy most domestic bathrooms/en-suites? Hoe do i work it out?
  11. N

    Printer colour use

    When using printer to print colour and black, does cartridges use colour cartridge to print the colour AND black, or colour cartridge for colour and black cartridge for black? I've got a HP PSC 1610. Its just my old printer used the colour cartridge for the black if it had the slightest bit of...
  12. N

    ELI Test On Smoke Alarms Circuits

    If its a TN-S system can i just presume 0.35ohms? Or do i have to test it with a meter?
  13. N

    ELI Test On Smoke Alarms Circuits

    What would you do, disconnect smokes before EFLI test?
  14. N

    Security Lighting

    When installing and outside light, using 3core flex, is it neccesary to use any conduit etc between inside/outside wall? Is it acceptable to just drill straight through and having cable bridging cavity? Does hole have to be made good for fire protection?
  15. N

    ELI Test On Smoke Alarms Circuits

    Yeah but couldnt find about smokes. Just thought current from ELI light damage circuit boards in smokes, thats all. Cheers for reply
  16. N

    ELI Test On Smoke Alarms Circuits

    Can you do a ELI test on circuits containing Smoke Alarms? I know you cant do IR tests on them , but not sure about ELI. Can someone please clarify
  17. N

    Fitting Spots above Cooker

    Some people i know are having their range cooker moved into the under stairs part of their kitchen. The distance between the cooking surface and the ceil part of the under stairs is only 600mm. They want spots fitting in this ceiling part. Would that be ok? Isn't 600mm a bit short a distance...
  18. N

    SW Sleeving

    So which is best, short piece or full length piece?
  19. N

    SW Sleeving

    When you put brown sleeving on a switch wire to indicate it is a switch wire, do you put sleeving so it completly covers the blue or just enough to indicate it is a SW?
  20. N

    Security Light

    So is a SP switch against regs or simply bad practice? Dont worry i'll use a DP